250R Mig Welding Setup; 250R Mma Welding Setup - Linde BOC RAPTOR 250R MIG Operating Manual

Table of Contents

Advertisement

18
BOC RAPTOR 200C & 250R MIG Operating manual
Front and back of power source
9
10
1
2
3
4
5
6
8
7
1 2T/4T switch
2 Process selection
3 Inductance adjustment
4 Current/wire speed
adjustment
5 Voltage adjustment
6 Positive terminal
7 Polarity switch connector

6.3 250R MIG Welding Setup

1 Ensure the machine is correctly plugged into the main circuit
2 Proper PPE must be worn
3 Ensure workplace safety such as fume extraction is in place
4 Switch machine on using On/Off switch 12 at the back of the
machine
5 Open gas cylinder and set gas flow rate
6 The REM indicator light goes on when the power source and wire
feeder are connected. This means the wire speed feed 15 and
voltage 18 will need to be adjusted on the wire feeder control
panel
7 Set voltage and wire feed speed (the tables included in this
manual can be used as a guideline for voltage and wire speed
selection)
8 Voltage is set by adjusting voltage knob 18 on wire feeder
9 Inductance can be changed by adjusting the
power source. The value will be displayed on the power source
control panel while welding
10 Welding wire can be fed through the torch by selecting the
"Wire Inch" button 17 on the wire feeder
11 For certain types of self shielded flux cored wires it is required to
change the polarity. This can be achieved by switching the work
return lead and clamp from the negative dinse connector 8 to
the positive dinse connector 6. The pigtail needs to then change
from the positive dinse connector 6 to the negative dinse
connector 8.
NOTE
Refer to the Control Panels section for a complete explanation of
all functionalities.
11
12
13
14
8 Negative terminal
9 Thermal protection/fault indicator
10 REM (Remote Equipment Activation)
11 Primary power connection
12 Power switch
13 Wire feeder control connection
14 Wire feeder mechanical connection
3 on the
Front and back of wire feeder
15
16
15 Wire speed
16 MIG torch euro connection
17 Wire inch
18 Voltage adjustment
19 Shielding gas connection
20 Cable connection (14 pin control)
21 Wire feeder mechanical power connection (refer to 14)

6.4 250R MMA Welding Setup

1 Ensure the machine is correctly plugged into the main circuit
2 Proper PPE must be worn
3 Ensure workplace safety such as fume extraction is in place
4 Fit work return lead to negative dinse* 8
5 Fit electrode holder to positive dinse connector* 6
6 Switch machine on using On/Off switch 12 at the back of
the machine
7 Select process by depressing the process selection switch 2
to MMA
8 Select amperage by turning by wire feed speed/Arc current
knob 4
*
DCEP Connection. For DCEN when recommended by the
consumable supplier, reverse the terminals as stated in
points 4 & 5.
17
18
19
20
21

Advertisement

Table of Contents
loading

This manual is also suitable for:

Boc raptor 200c mig

Table of Contents