  • Page 3: Preliminary Note

    CR1204 1 Preliminary note You will find instructions, technical data, approvals and further information using the QR code on the unit / packaging or at www.ifm.com. 1.1 Symbols used Requirement Instructions Reaction, result [...] Designation of keys, buttons or indications Cross-reference Important note Non-compliance may result in malfunction or interference.
  • Page 4: Safety Instructions

    CR1204 2 Safety instructions • The unit described is a subcomponent for integration into a system. – The system architect is responsible for the safety of the system. – The system architect undertakes to perform a risk assessment and to create documentation in accordance with legal and normative requirements to be provided to the operator and user of the system.
  • Page 5: Intended Use

    If required, take appropriate EMC screening measures. The unit is not approved for safety-related tasks in the field of operator protection. 3.1 Application example Fig. 1: Networking of 4 analogue cameras with an ecomatDisplay ecomatDisplay CR1204 analogue cameras (e.g. 4 x O2M200) 3.2 Properties •...
  • Page 6 Feature CR1204 Touch screen ● Freely programmable, backlit buttons Navigation keys with button Ethernet interfaces CAN interfaces ifm plug&play (CAN based) USB 2.0 interfaces Analogue video inputs Digital inputs B Digital outputs 2.5 A Line In Speaker output Headphone output Controller Quad core with GPU, 1.2 GHz...
  • Page 7: Installation

    EC0732, installation kit for panel mounting • EC1410...EC1414, RAM® mount system for surface mounting More information about available accessories at www.ifm.com 4.2 General installation instructions The following applies to all types of mounting: The responsibility for the compliance with the requirements concerning mounting of the device in the application with regard to shock, vibration, acceleration and weight lies with the system architect.
  • Page 8: Light Sensor And Status Led

    CR1204 38,1 ® 4 x M5 threaded hole for RAM mount system / for the fixing profile of the installation kit pressure compensation element ATTENTION The device is equipped with a pressure compensation element. Sealing or closing the corresponding ventilation ducts with elastic materials may damage the device. u Do not use any sealing materials in the area around the pressure compensation elements.
  • Page 9: Panel Mounting / Control Cabinet Installation

    CR1204 4.3 Panel mounting / control cabinet installation 4.3.1 Safety instructions for panel mounting / control cabinet installation The specifications for the operating temperature apply in front of and behind the installation surface. The dimensions for the control panel cut-out are a basic prerequisite for the requirements concerning electrical protection, fire protection and protection rating of the device / system.
  • Page 10: Installation With Installation Kit

    CR1204 4.3.2 Installation with installation kit The installation kit enables horizontal, vertical or overhead mounting of the device in a panel cut-out. This type of mounting is suited for materials with a thickness from 1 to 10 mm. The fixing blocks, M5 set screws, washers, and M5 hexagon nuts required for mounting are supplied with the installation kit.
  • Page 11: Surface Mounting With Ram® Mount System

    CR1204 ATTENTION Contact corrosion between the mounting screws and the housing. w Damage to the device u Do not use copper or nickel-plated materials for the bolting elements. u Use zinc-plated screws. u In very corrosive environments such as extremely salty air, use screws with surface finishing on a zinc/nickel basis with thick-film passivation and sealing.
  • Page 12: Mounting Steps

    2: mounting plate with ball head ® You will find more information about the available RAM mount components at: www.ifm.com 4.4.1 Mounting steps u Screw the mounting plate to the back of the device. Usable M5 thread depth: ≤ 8 mm ±0.5...
  • Page 13: Electrical Connection

    5.1 Wiring Wiring: Technical data: www.ifm.com The terminals may only be supplied with the signals specified in the technical data or on the device label Unconnected pins must not be connected to the cable harness and its individual cores must be sealed.
  • Page 14: General Wiring Information

    Use twisted-pair cables for the CAN / IFM connection. The CAN bus is internally protected against short circuit to VBB and GND. For CAN / IFM cables ≥ 30 m, ensure appropriate protection against surge (e. g. shielded cables).
  • Page 15 CR1204 Fig. 9: Connectors (back of the device) Supply, inputs/outputs, video, audio, CAN, ifm, service USB0 USB1 ETH0 ETH1 ATTENTION Wrong connection may cause damage to the device. u Observe the safety instructions. ATTENTION The short-circuit / reverse polarity protection of the device applies to the operating voltage connections.
  • Page 16: Operating Voltage And Circuit Breakers

    CR1204 5.5 Operating voltage and circuit breakers u The individual electric circuits must be protected in order to protect the whole system. Automotive spade-type fuses are recommended. Required triggering Designation Connector 1 Operating voltage Nominal value fuse characteristics Pin 119 8...16 V DC and 16… ≤...
  • Page 17: Ethernet Interface

    CR1204 Fig. 10: Shield connection To avoid contact corrosion on the shield connection of the housing, do not use any copper or nickel-plated materials for the bolting elements! u In very corrosive environments such as extremely salty air, use screws with surface finishing on a zinc/nickel basis with thick-film passivation and sealing.
  • Page 18: Usb Interfaces

    CR1204 5.9 USB interfaces Wiring: Technical data: www.ifm.com This USB interface is connected to a USB connector in the control panel or in the dashboard. It is used for the connection of USB 2.0 devices. The supply of external USB devices via the USB interface is protected against overload and overvoltage.
  • Page 19 CR1204 Use headphones with an impedance of ≥ 16 Ω .
  • Page 20: Set-Up

    In addition to the CODESYS programming system, the following documents are required for programming and set-up of the device: • Programming manual ecomatDisplay Manuals as well as online help CODESYS and ecomatDisplay are available for download on the internet: www.ifm.com...
  • Page 21: Function Of The Internal Temperature Sensor

    Current consumption (display illumination etc.) The device heats up considerably under demanding operating conditions. The device temperature must not exceed the maximum permissible value (Technical data: www.ifm.com). The value provided by the internal temperature sensor can e.g. be used for the following actions: •...
  • Page 22: Maintenance, Repair And Disposal

    CR1204 7 Maintenance, repair and disposal 7.1 Battery change The battery may only be changed by a qualified person. u Before changing the battery, fully separate the device from supply voltage. Battery may explode if handled incorrectly. Do not recharge or disassemble the battery, nor dispose of it in fire.
  • Page 23: Cleaning The Display Surface

    Remove the battery and replace it with a new one. Observe the polarity: positive side up Battery type (Technical data: www.ifm.com) u Check sealing areas and sealing for soiling. Clean them, if necessary. u Screw the service cover with 3.0 Nm to restore the protection rating (width across flats 13 or ¼“).
  • Page 24: Disposal

    CR1204 7.5 Disposal u Dispose of used batteries in accordance with the national environmental regulations. Do not dispose of used batteries as household waste. u Dispose of the unit in accordance with the national environmental regulations.