IFM ecomatDisplay CR1074 Installation Instructions Manual

IFM ecomatDisplay CR1074 Installation Instructions Manual

Process and dialogue module

Advertisement

Quick Links

Installation instructions
Process and dialogue module
UK
ecomatDisplay
CR1074
CR1075
CR1076
CR1077

Advertisement

Table of Contents
loading

Summary of Contents for IFM ecomatDisplay CR1074

  • Page 1 Installation instructions Process and dialogue module ecomatDisplay CR1074 CR1075 CR1076 CR1077...
  • Page 2: Table Of Contents

    Process and dialogue module ecomatDisplay CR1074, CR1075, CR1076, CR1077 Contents 1 Preliminary note � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � 4 1�1 Key to the symbols �...
  • Page 3 Process and dialogue module ecomatDisplay CR1074, CR1075, CR1076, CR1077 7�2 CR1075 � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � 32 7�3 CR1076 �...
  • Page 4: Preliminary Note

    Process and dialogue module ecomatDisplay CR1074, CR1075, CR1076, CR1077 1 Preliminary note Technical data, approvals, accessories and further information at www�ifm�com� 1.1 Key to the symbols ► Instructions > Reaction, result […] Designation of keys, buttons or indications → Cross-reference Important note Non-compliance may result in malfunction or interference�...
  • Page 5: Safety Instructions

    Process and dialogue module ecomatDisplay CR1074, CR1075, CR1076, CR1077 2 Safety instructions ● The device described is a subcomponent for integration into a system� The manufacturer is responsible for the safety of the system� The system creator undertakes to perform a risk assessment and to create documentation in accordance with legal and normative requirements to be provided to the operator and user of the system�...
  • Page 6: Functions And Features

    Process and dialogue module ecomatDisplay CR1074, CR1075, CR1076, CR1077 3 Functions and features The process and dialogue module is a programmable graphic display for controlling, parameter-setting and operation of mobile machines and plants� It is suited for use at an operating altitude of 3000 m above sea level even under severe conditions, such as an extended temperature range and mechanical stress, see (→...
  • Page 7: 3�2 Overview Of The Common Characteristics

    Process and dialogue module ecomatDisplay CR1074, CR1075, CR1076, CR1077 3.2 Overview of the common characteristics ● 7" colour display ● Closed metal housing suitable for panel mounting and surface mounting outside or in the cabin ● Freely programmable to IEC 61131-3 with target visualisation ●...
  • Page 8: Installation

    Process and dialogue module ecomatDisplay CR1074, CR1075, CR1076, CR1077 4 Installation 4.1 Mounting accessories The device is supplied without mounting accessories� Depending on the intended installation location and type of mounting, the following mounting accessories are available: ● EC0731, installation kit for panel mounting ●...
  • Page 9: 4�2�1 Locator For Mounting Accessories

    Process and dialogue module ecomatDisplay CR1074, CR1075, CR1076, CR1077 4.2.1 Locator for mounting accessories The back of the device has been prepared for fixing the mounting accessories� 38,1 1: 4 x M5 threaded hole for RAM mount system / for the fixing profile of the installation kit ®...
  • Page 10: 4�2�2 Light Sensor And Status Led

    Process and dialogue module ecomatDisplay CR1074, CR1075, CR1076, CR1077 4.2.2 Light sensor and status LED The device is equipped with a light sensor� It is used to adapt the brightness and the operating elements automatically to the ambient brightness conditions�...
  • Page 11 Process and dialogue module ecomatDisplay CR1074, CR1075, CR1076, CR1077 WARNING! The housing does not meet the requirements concerning protective earth� Only functional grounding is possible� > Risk of electrical shock in case of hazardous active voltages in the control cabinet behind the installation surface�...
  • Page 12: 4�3�2 Installation With Installation Kit

    Process and dialogue module ecomatDisplay CR1074, CR1075, CR1076, CR1077 CAUTION! The use of the installation kit does not ensure the requirements concerning the protection rating of the system with the installed device� > Protection rating and electrical protection might be impaired ►...
  • Page 13: 4�3�3 Panel Cut-Out

    Process and dialogue module ecomatDisplay CR1074, CR1075, CR1076, CR1077 4.3.3 Panel cut-out ► Make a cut-out� 4 x R7 Tolerances: ± 0�5 mm Panel cut-out 4.3.4 Mounting steps ► Screw the set screws into the M5 thread on the back of the device�...
  • Page 14 Process and dialogue module ecomatDisplay CR1074, CR1075, CR1076, CR1077 NOTE! Contact corrosion between the mounting screws and the housing� > Damage to the device ► Do not use copper or nickel-plated materials for the bolting elements� ► Use zinc-plated screws�...
  • Page 15: 4�4 Surface Mounting With Ram ® Mount System

    Process and dialogue module ecomatDisplay CR1074, CR1075, CR1076, CR1077 4.4 Surface mounting with RAM mount system ® Using the RAM mount set, available as accessories, the device can be used as a ® firmly mounted desktop unit� Two ball heads allow variable orientation of the unit�...
  • Page 16: 4�5 Other Installation Types

    Process and dialogue module ecomatDisplay CR1074, CR1075, CR1076, CR1077 4.5 Other installation types Permissible installation types: (→ 4.3 Panel mounting / control cabinet installation) (→ 4.4 Surface mounting with RAM mount system) ® All other installation types are in the sole responsibility of the system creator�...
  • Page 17: 5�2 Connection Accessories

    Process and dialogue module ecomatDisplay CR1074, CR1075, CR1076, CR1077 NOTE! Reverse polarity protection not ensured in case of power supply SELV/ PELV on VBB and VBB Reverse polarity protection is only ensured in case of supply via the on-board system (via a battery), if the polarity of the supply is reversed as a whole (battery connected incorrectly).
  • Page 18: 5�4 General Wiring Information

    ► Use twisted-pair cables for the CAN / IFM connection� The CAN bus is internally protected against short circuit to VBB and GND. For CAN / IFM cables ≥ 30 m, ensure appropriate protection against surge (e� g. shielded cables).
  • Page 19: 5�5 Operating Voltage And Fuses

    Process and dialogue module ecomatDisplay CR1074, CR1075, CR1076, CR1077 NOTE! The short-circuit / reverse polarity protection of the device applies to the operating voltage connections� A short circuit between operating voltage VBB and USB / audio / video might cause damage to the device�...
  • Page 20: 5�6 Shield Connection

    Process and dialogue module ecomatDisplay CR1074, CR1075, CR1076, CR1077 Supply cables of the inputs can be secured together with the circuit breaker for � NOTE! Load dump and surge without connection of VBB > Destruction of the device possible! ► Always connect VBB , even if the outputs are not used or are not available�...
  • Page 21: 5�7 Ethernet Interface

    Process and dialogue module ecomatDisplay CR1074, CR1075, CR1076, CR1077 5.7 Ethernet interface Communication interfaces are insulated from each other, from other circuits and from device surfaces that can be touched, with basic insulation according to IEC 60950-1 (secondary circuit with max� operating voltage (→ 7 Technical data), supplied from the mains circuit up to 300 V of overvoltage category II).
  • Page 22: 5�9�1 Short-Circuit Protection

    Process and dialogue module ecomatDisplay CR1074, CR1075, CR1076, CR1077 ≤ 1,8 m USB connection via M12 connector 1: Dialogue module 2: USB connector, for example, in the control panel or in the dashboard 3: USB device Permanent connection: Dialogue module – USB connector ►...
  • Page 23: 5�10 Selection Of Loudspeakers

    Process and dialogue module ecomatDisplay CR1074, CR1075, CR1076, CR1077 5.10 Selection of loudspeakers For optimum audio output, use 8 Ω loudspeakers� Use headphones with an impedance of ≥ 16 Ω� 6 Set-up 6.1 General The factory setting of the device shows a demo application� The installed recovery app can be used to load any suitable firmware version to the device�...
  • Page 24: 6�3 Set-Up

    Process and dialogue module ecomatDisplay CR1074, CR1075, CR1076, CR1077 6.3 Set-up The set-up allows setting the device parameters directly via the local display or the web interface of the device� Select the set-up button in the App Launcher to start the local set-up�...
  • Page 25 Process and dialogue module ecomatDisplay CR1074, CR1075, CR1076, CR1077 NOTE! Internal temperature exceeds the permissible value (→ 7 Technical data) > Malfunction or damage to the device possible ► Reduce device temperature� ► Take appropriate measures to prevent further heating up of the...
  • Page 26: Technical Data

    Process and dialogue module ecomatDisplay CR1074, CR1075, CR1076, CR1077 7 Technical data Control systems 7.1 CR1074 P_MZ_e100_0097 Original Scale Drawing (MTD) Scale: 70% CR1074 223,6 Process and dialogue module ecomatDisplay 7" colour display 6 freely programmable backlit function keys Navigation keys with button...
  • Page 27 Process and dialogue module ecomatDisplay CR1074, CR1075, CR1076, CR1077 Control systems CR1074 Technical data Protection rating IP 65 / IP 67 (for inserted connectors with individually sealed cores and inserted M12 connectors/sealing caps M12 connectors/sealing caps) Ambient temperature -35...65° C (up to 2000 m above sea level) -35...60°...
  • Page 28 Process and dialogue module ecomatDisplay CR1074, CR1075, CR1076, CR1077 Control systems CR1074 Technical data Other features Acoustic signal output integrated audio stereo output Stereo Class D speaker output with 1 W per channel, 8 Ω, BTL Temperature monitoring 1 integrated probe for measuring the main board temperature The main board temperature must not exceed 85 °C�...
  • Page 29 Process and dialogue module ecomatDisplay CR1074, CR1075, CR1076, CR1077 Control systems CR1074 Technical data Test standards and regulations CE mark EN 61000-6-2 Electromagnetic compatibility (EMC) Immunity EN 61000-6-4 Electromagnetic compatibility (EMC) Emission E1 mark UN/ECE-R10 Noise emission Noise immunity with 45 V/m ISO 7637-2 Pulse 1, severity level: IV;...
  • Page 30 Process and dialogue module ecomatDisplay CR1074, CR1075, CR1076, CR1077 Control systems CR1074 Technical data Back of the unit 1: AMP connector, 40 poles 2: Locator for the RAM® mount system and mounting frame 3: M12 connector, 5 poles 4: M12 connector, 4 poles...
  • Page 31 Process and dialogue module ecomatDisplay CR1074, CR1075, CR1076, CR1077 Control systems CR1074 Technical data Wiring (1) Supply, audio, CAN, service not connected not connected not connected not connected CAN0_L not connected CAN1_L not connected not connected not connected not connected...
  • Page 32: 7�2 Cr1075

    Process and dialogue module ecomatDisplay CR1074, CR1075, CR1076, CR1077 Control systems 7.2 CR1075 P_MZ_e100_0097 Original Scale Drawing (MTD) Scale: 70% CR1075 223,6 Process and dialogue module ecomatDisplay 7" colour display 6 freely programmable backlit function keys Navigation keys with button...
  • Page 33 Process and dialogue module ecomatDisplay CR1074, CR1075, CR1076, CR1077 Control systems CR1075 Technical data Protection rating IP 65 / IP 67 (for inserted connectors with individually sealed cores and inserted M12 connectors/sealing caps) Ambient temperature -35...65° C (up to 2000 m above sea level) -35...60°...
  • Page 34 Process and dialogue module ecomatDisplay CR1074, CR1075, CR1076, CR1077 Control systems CR1075 Technical data Other features Acoustic signal output integrated audio stereo output Stereo Class D speaker output with 1 W per channel, 8 Ω, BTL Temperature monitoring 1 integrated probe for measuring the main board temperature The main board temperature must not exceed 85 °C�...
  • Page 35 Process and dialogue module ecomatDisplay CR1074, CR1075, CR1076, CR1077 Control systems CR1075 Technical data Test standards and regulations CE mark EN 61000-6-2 Electromagnetic compatibility (EMC) Immunity EN 61000-6-4 Electromagnetic compatibility (EMC) Emission E1 mark UN/ECE-R10 Noise emission Noise immunity with 45 V/m ISO 7637-2 Pulse 1, severity level: IV;...
  • Page 36 Process and dialogue module ecomatDisplay CR1074, CR1075, CR1076, CR1077 Control systems CR1075 Technical data Back of the unit 1: AMP connector, 40 poles 2: Locator for the RAM® mount system and mounting frame 3: M12 connector, 5 poles 4: M12 connector, 4 poles...
  • Page 37 Process and dialogue module ecomatDisplay CR1074, CR1075, CR1076, CR1077 Control systems CR1075 Technical data Wiring (1) supply, inputs/outputs, video, audio, CAN, ifm, service not connected VIDEO0_GND IFM0- VIDEO1_GND CAN0_L not connected CAN1_L not connected CAN2_L not connected CAN3_L not connected...
  • Page 38: 7�3 Cr1076

    Process and dialogue module ecomatDisplay CR1074, CR1075, CR1076, CR1077 Control systems 7.3 CR1076 P_MZ_e100_0097 Original Scale Drawing (MTD) Scale: 70% CR1076 223,6 Process and dialogue module ecomatDisplay 7" colour display 6 freely programmable backlit function keys Navigation keys with button...
  • Page 39 Process and dialogue module ecomatDisplay CR1074, CR1075, CR1076, CR1077 Control systems CR1076 Technical data Protection rating IP 65 / IP 67 (for inserted connectors with individually sealed cores and inserted M12 connectors/sealing caps) Ambient temperature -35...65° C (up to 2000 m above sea level) -35...60°...
  • Page 40 Process and dialogue module ecomatDisplay CR1074, CR1075, CR1076, CR1077 Control systems CR1076 Technical data Other features Audio input Stereo Line In default input level: -10 dBV (= 0,316 V) max. input level: 0 dBV (= 1 V) Acoustic signal output integrated audio stereo output Stereo Class D loudspeaker output with 1W per channel, 8 Ω, BTL...
  • Page 41 Process and dialogue module ecomatDisplay CR1074, CR1075, CR1076, CR1077 Control systems CR1076 Technical data Test standards and regulations CE mark EN 61000-6-2 Electromagnetic compatibility (EMC) Immunity EN 61000-6-4 Electromagnetic compatibility (EMC) Emission E1 mark UN/ECE-R10 Noise emission Noise immunity with 45 V/m ISO 7637-2 Pulse 1, severity level: IV;...
  • Page 42 Process and dialogue module ecomatDisplay CR1074, CR1075, CR1076, CR1077 Control systems CR1076 Technical data Back of the unit 1: AMP connector, 40 poles 2: Locator for the RAM® mount system and mounting frame 3: M12 connector, 5 poles 4: M12 connector, 5 poles...
  • Page 43 Process and dialogue module ecomatDisplay CR1074, CR1075, CR1076, CR1077 Control systems CR1076 Technical data Wiring (1) supply, inputs/outputs, video, audio, CAN, ifm, service VIDEO3_GND VIDEO0_GND IFM0- VIDEO1_GND CAN0_L VIDEO2_GND CAN1_L AUDIO_IN_R CAN2_L AUDIO_GND CAN3_L HEAD_OUT_R IFM1- AUDIO_OUT_R- SERVICE1 AUDIO_OUT_L- VIDEO3_SIGNAL...
  • Page 44: 7�4 Cr1077

    Process and dialogue module ecomatDisplay CR1074, CR1075, CR1076, CR1077 Control systems 7.4 CR1077 P_MZ_e100_0097 Original Scale Drawing (MTD) Scale: 70% CR1077 223,6 Process and dialogue module ecomatDisplay 7" colour display, touch screen 6 freely programmable backlit function keys Navigation keys with button...
  • Page 45 Process and dialogue module ecomatDisplay CR1074, CR1075, CR1076, CR1077 Control systems CR1077 Technical data Background illumination operating RGB LED, colours and states programmable by means of the application software elements Protection rating IP 65 / IP 67 (for inserted connectors with individually sealed cores and inserted...
  • Page 46 Process and dialogue module ecomatDisplay CR1074, CR1075, CR1076, CR1077 Control systems CR1077 Technical data Other features Audio input Stereo Line In default input level: -10 dBV (= 0.316 V) max. input level: 0 dBV (= 1 V) Acoustic signal output integrated audio stereo output Stereo Class D loudspeaker output with 1W per channel, 8 Ω, BTL...
  • Page 47 Process and dialogue module ecomatDisplay CR1074, CR1075, CR1076, CR1077 Control systems CR1077 Technical data Test standards and regulations CE mark EN 61000-6-2 Electromagnetic compatibility (EMC) Immunity EN 61000-6-4 Electromagnetic compatibility (EMC) Emission E1 mark UN/ECE-R10 Noise emission Noise immunity with 45 V/m ISO 7637-2 Pulse 1, severity level: IV;...
  • Page 48 Process and dialogue module ecomatDisplay CR1074, CR1075, CR1076, CR1077 Control systems CR1077 Technical data Back of the unit 1: AMP connector, 40 poles 2: Locator for the RAM® mount system and mounting frame 3: M12 connector, 5 poles 4: M12 connector, 5 poles...
  • Page 49 Process and dialogue module ecomatDisplay CR1074, CR1075, CR1076, CR1077 Control systems CR1077 Technical data Wiring (1) supply, inputs/outputs, video, audio, CAN, ifm, service VIDEO3_GND VIDEO0_GND IFM0- VIDEO1_GND CAN0_L VIDEO2_GND CAN1_L AUDIO_IN_R CAN2_L AUDIO_GND CAN3_L HEAD_OUT_R IFM1- AUDIO_OUT_R- SERVICE1 AUDIO_OUT_L- VIDEO3_SIGNAL...
  • Page 50: Maintenance, Repair And Disposal

    Process and dialogue module ecomatDisplay CR1074, CR1075, CR1076, CR1077 8 Maintenance, repair and disposal 8.1 Battery change The battery may only be changed by a qualified person ► Before changing the battery, fully separate the device from supply voltage� 1: service cover 2: battery ►...
  • Page 51: 8�2 Cleaning The Display Surface

    Process and dialogue module ecomatDisplay CR1074, CR1075, CR1076, CR1077 NOTE! The protection rating does not apply if the service cover is open and there is no ESD protection of the accessible contacts inside > Damage to the device possible ► Clean the area around the service cover before opening it�...
  • Page 52: 8�3 Cleaning The Housing Surface

    Process and dialogue module ecomatDisplay CR1074, CR1075, CR1076, CR1077 8.3 Cleaning the housing surface ► Disconnect the device� ► Clean the device from dirt using a soft, chemically untreated and dry cloth� ► In case of severe soiling, use a damp cloth�...

Table of Contents