Siemens SITRANS FM100 Operating Instructions Manual page 56

Electromagnetic flowmeters
Table of Contents

Advertisement

Index 
Name 
[hex] 
0x0110 
OUT1Source 
0x0111 
OUT1Type 
0x0112 
OUT1Alarm 
Function 
0x0113 
OUT1AlarmOutput
Type 
0x0114 
OUT1AlarmSwitch 
Function 
0x0115 
OUT1Alarm 
Threshold 
0x0119 
OUT1AlarmLower 
Threshold 
0x011D 
OUT1Alarm 
Hysteresis 
0x0121 
OUT1Alarm 
SuppressionFactor 
0x0122 
OUT1Alarm 
Suppression 
Direction 
A5E48762204-AB
Description 
Factory default 
Source for the 
output  
(production 
setting) 
Configuration of 
the output: 0‐
20mA, Pulse, 
Frequency  
(production 
setting) 
Limit or window 
function for the 
alarm output 
Alarmoutput NPN, 
PNP or Pushpull 
Alarmoutput 
normally opened 
or closed 
Threshold for the 
1,0 
alarmoutput 
Threshold for the 
1,0 
alarmoutput used 
by the 
windowfunction 
Switching 
1,0 
hysteresis for the 
alarmoutput 
How many times 
the threshold must 
be hit in order to 
switch the alarm 
output 
for which direction 
the suppression 
factor is used 
SITRANS FM100
Max Value 
Min Value 
(0) ‐ Flow 
(1) ‐ Volume 
(2) ‐ Temperature 
(3) ‐ Part Volume 
(0) ‐ disabled 
(1) ‐ Alarm Output 
(2) ‐ 4‐20mA 
(3) ‐ 0‐20mA 
(4) ‐ 2‐10V 
(5) ‐ 0‐10V 
(6) ‐ Pulse Output 
(7) ‐ Frequency Output 
(8) ‐ M12COM 
(9) ‐ IO‐Link 
(10) ‐ Control Input 
(0) ‐ Limit 
(1) ‐ Window 
(0) ‐ NPN 
(1) ‐ PNP 
(2) ‐ PushPull 
(0) ‐ normally opened 
(1) ‐ normally closed 
MRE 
MRS 
OUT1AlarmT
MRS 
hreshold 
9999,0 
‐9999,0 
60 
(0) ‐ Up 
(1) ‐ Down 
(2) ‐ Both 
Length 
Data Type 
Access 
[Bytes] 
UIntegerT 
  
UIntegerT 
  
UIntegerT 
R/W 
UIntegerT 
R/W 
UIntegerT 
R/W 
FloatT 
R/W 
FloatT 
R/W 
FloatT 
R/W 
UIntegerT 
R/W 
UIntegerT 
R/W 