HTX30 Product Manual
External CAN bus terminators
External CAN bus terminator links are supplied with each station control panel. Fit these to the following
connectors:
The unused JIM1 connector (In multi-station installations only).
The SCP connector on the last station control panel in the chain. This terminator is not required if an
external control interface module or a JETanchor control module is connected to the SCP.
The last control input device at each station.
Failure to connect the terminators will result in communication errors between modules.
A
Control Station 1
B
Control Station 2
C
Control Station 3
1
Terminator at JIM1 connector
2
Terminator at SCP connector at last station control panel
3
Terminator at last control input device per station
Figure 15: External CAN bus terminators
4-13