For example, projectors that have a HD greater than 1 m and emit light into an uncontrolled area where
persons may be present should be positioned in accordance with "the fixed projector installation" parameters,
resulting in a HD that does not extend into the audience area unless the beam is at least 2.0 meter above the
floor level. In environments where unrestrained behavior is reasonably foreseeable, the minimum separation
height should be greater than or equal to 3.0 meter to prevent potential exposure, for example by an individual
sitting on another individual's shoulders, within the HD. Sufficiently large separation height may be achieved
by mounting the image projector on the ceiling or through the use of physical barriers.
RA
SIDE VIEW (A)
PR
H<SH
RZ
LRZ
Image 1–1
A
Side view
B
Top view
RA
Restricted Access location (boot area of projector).
TH
Theater
RZ
Restriction Zone in the theater
Based on national requirements, no person is allowed to enter the projected beam within the zone between
the projection lens and the related hazard distance (HD). This shall be physically impossible by creating
sufficient separation height or by placing barriers. The minimum separation height takes into account the
surface upon which persons other than operator, performers or employees are permitted to stand.
On
Image 1– 2
a typical setup is displayed. It must be verified if these minimum requirements are met. If
required a restricted zone (RZ) in the theater must be established. This can be done by using physical barrier,
like a red rope as illustrated in
The restricted area sticker can be replaced by a sticker with only the symbol.
Image 1–2
USA market
For LIPs (Laser Illuminated Projectors) installed in the USA market other restriction zone conditions apply.
TH
SH
H>SH
Image
1–2.
TOP VIEW (B)
RZ
RA
EXIT
LRZ
HD
Hazard Distance
LRZ
Length Restriction Zone in the theater
H
Height between surface floor and the light beam
SH
Separation Height
SW
Separation Width
Safety
TH
SW
SW
R5916677 /00
G50