PR electronics 3186A Product Manual

PR electronics 3186A Product Manual

2-wire transmitter isolator, 2-wire current isolator

Advertisement

Quick Links

Product manual
3186A:
2-wire transmitter isolator
3186B:
2-wire current isolator
ZONE 2
Zone 2
T E M P E R AT U R E
|
I . S . I N T E R FA C E S
No. 3186V102-UK
Se r ia l n o .: 17 13390 01- 22131 9036
ZONE 2 / DIV 2
|
CO M M U N I C AT I O N I N T E R FA C E S
|
M U LT I F U N C T I O N A L
|
I S O L AT I O N
|
D I S P L AY

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the 3186A and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for PR electronics 3186A

  • Page 1 Product manual 3186A: 2-wire transmitter isolator 3186B: 2-wire current isolator ZONE 2 Zone 2 ZONE 2 / DIV 2 T E M P E R AT U R E I . S . I N T E R FA C E S...
  • Page 2 6 Product Pillars to meet your every need Individually outstanding, unrivalled in combination With our innovative, patented technologies, we make signal conditioning smarter and simpler. Our portfolio is composed of six product areas, where we offer a wide range of analog and digital devices covering over a thousand applications in industrial and factory automation.
  • Page 3: Table Of Contents

    3186A: 2-wire transmitter isolator 3186B: 2-wire current isolator Table of contents Warning ....................
  • Page 4: Warning

    To avoid explosion and serious injury: Devices having mechanical failures must be returned to PR electronics for repair or replacement. Repair of the device must be done by PR electronics A/S only. Warning In applications where hazardous voltage is connected to in-/outputs of the device, sufficient spacing or isolation from wires, terminals and enclosure - to surroundings (incl.
  • Page 5 Should there be any doubt as to the correct handling of the device, please contact your local distributor or, alternatively, PR electronics A/S www.prelectronics.com Mounting and connection of the device should comply with national legislation for mounting of electric materials, i.e. wire cross section, protective fuse, and location.
  • Page 6 For installation on power rail in Zone 2, only Power Rail type 9400 supplied by Power Control Unit type 9410 is allowed. To prevent ignition of the explosive atmospheres, disconnect power before servicing and do not separate connectors when energised and an explosive gas mixture is present. Do not mount or remove devices from the power rail when an explosive gas mixture is present.
  • Page 7: How To Demount System 3000

    How to demount system 3000 Picture 1: Mounting on DIN rail. Click the device onto the rail. Picture 2: Demounting from DIN rail. First, remember to demount the connectors with hazardous voltages. Detach the device from the DIN rail by lifting the bottom lock. Picture 3: Wire size AWG 26-12 / 0.13 x 2.5 mm stranded wire.
  • Page 8: Installation On Din Rail

    Installation on DIN rail Module stop 3186 must be supported by a module stop for marine applications. (PR part number 9404). Marking The front cover of the 3100 series has been designed with an area for affixation of a click-on marker. The area assigned to the marker measures 5 x 7.5 mm.
  • Page 9: Side Label

    Side label Terminal numbers 3186A2 Type no. connections Approvals 3186B2 Terminal numbers Type no. connections Approvals 3186V102-UK...
  • Page 10: Application

    • Excellent accuracy, better than 0.05% • Slimline 6 mm housing Application • 3186A is a 1:1 output loop-powered 2-wire transmitter isolator that excites and measures passive input signals. • 3186B is a 1:1 output loop-powered 2-wire current isolator that measures active input signals. •...
  • Page 11: Order

    3186A ........
  • Page 12 In order to ensure that the maximum internal temperature is not exceeded, the following exceptions must be followed for the 3186B1 & B2. 3186B1 Power dissipation @ T = 70°C: amb. 1450 Undervoltage condition 1000 Correct operating range Temperature limitation @ Tamb.
  • Page 13 Input and output specifications: Available input transmitter (Tx) supply (3186A) ....3.5...32.5 V Signal range, input to output ......3.8...20.5 mA Signal conversion .
  • Page 14 Observed authority requirements: EMC..........2014/30/EU LVD .
  • Page 15: Connections

    Connections 3186A + V supply 4...20 mA Input Output ch. 1 ch. 1 + V supply Input Output 4...20 mA ch. 2 ch. 2 3186B + V supply 4...20 mA Input Output ch. 1 ch. 1 + V supply Input Output 4...20 mA...
  • Page 16: Document History

    Document history The following list provides notes concerning revisions of this document. Rev. ID Date Notes 1710 Model 3186B added. Specifications for power dissipation added. PESO/CCOE approval added. 2108 PESO/CCOE approval discontinued. CCC approval added. ATEX and IECEx approvals updated - Ex na changed to Ex ec.
  • Page 17 We are near you, all over the world Our trusted red boxes are supported wherever you are All our devices are backed by expert service and a 5-year business with a global reach. This means that we are warranty. With each product you purchase, you receive always nearby and know your local markets well.
  • Page 18 Benefit today from PERFORMANCE MADE SMARTER PR electronics is the leading technology company specialized in making industrial process control safer, more reliable and more efficient. Since 1974, we have been dedicated to perfecting our core competence of innovating high precision technology with low power consumption.