Toshiba RAS-B07G3KVSG-E Service Manual page 112

Indoor/outdoor unit, r32 or r410a inverter
Hide thumbs Also See for RAS-B07G3KVSG-E:
Table of Contents

Advertisement

11-8-2. P .C . Board Layout
DB01
Diode Bridge
Rectifier
CN30
Power supply
Input terminal
(Line)
F01
Fuse
R-03
Resistor
L-01
Line Filter
CN31
Power supply
Input terminal
(Neutral)
CN28
Serial Signal
terminal
Note : Some component don't exist in the actual PCB. Refer to the actual product when servicing is priority.
[1] Sensor characteristic table
100
90
80
70
60
50
40
30
20
10
0
0
C03
F02
Main Electrolyte
Fuse
Capacitor
IC11
T01
Transformer
TD
TA, TC, TO, TS,TCJ, TE
10
20
30
40
Temperature (˚C)
CN36
CN32
Fan Motor
Stepping motor
Connector
IC14
TD
TA
TC, TCJ : Heat exchanger temp. sensor
TO
TS
TE
5
0
60
- 112 -
CN21
HA1 Connector
(Wireless Adapter)
CN10
Display
Connector
CN63(Red)
TCJ Sensor
Connector
CN62(Black)
TC Sensor
Connector
CN61(Yellow)
TA Sensor
Connector
: Discharge temp. sensor
: Room temp. sensor
: Outdoor temp. sensor
: Suction temp. sensor
: Outdoor heat exchanger temp
sensor

Advertisement

Table of Contents
loading

Table of Contents