Toshiba RAS-B07G3KVSG-E Service Manual page 26

Indoor/outdoor unit, r32 or r410a inverter
Hide thumbs Also See for RAS-B07G3KVSG-E:
Table of Contents

Advertisement

7-2. Operation Data
<Cooling>
Tempeature
condition(°C)
Indoor
Outdoor
27/19
35/-
RAS-B07G3KVSG-E
RAS-B07G3KVSGB-E
RAS-B10G3KVSG-E
RAS-B10G3KVSGB-E
RAS-B13G3KVSG-E
RAS-B13G3KVSGB-E
RAS-B16G3KVSG-E
RAS-B16G3KVSGB-E
<Heating>
Tempeature
condition(°C)
Indoor
Outdoor
20/-
7/6
RAS-B07G3KVSG-E
RAS-B07G3KVSGB-E
RAS-B10G3KVSG-E
RAS-B10G3KVSGB-E
RAS-B13G3KVSG-E
RAS-B13G3KVSGB-E
RAS-B16G3KVSG-E
RAS-B16G3KVSGB-E
NOTES : Measure surface temperature of heat exchanger pipe around center of heat exchanger path U bent.
(Thermistor themometer)
Model name
Standard
pressure
P (MPa)
1.1 to 1.2
1.1 to 1.2
1.0 to 1.1 10 to 12
1.0 to 1.1
Model name
Standard
pressure
P (MPa)
2.4 to 2.6 39 to 40
2.4 to 2.6 39 to 40
2.6 to 2.8 42 to 44
2.8 to 3.0 44 to 46
Heat exchanger
Indoor
pipe temp.
fan mode fan mode
T1 (°C)
T2 (°C)
12 to 13 45 to 46
High
High
12 to 13 45 to 46
High
48 to 50
9 to 10
49 to 51
High
Heat exchanger
Indoor
pipe temp.
fan mode fan mode
T1 (°C)
T2 (°C)
1 to 2
High
1 to 2
High
1 to 2
High
High
1 to 2
- 26 -
Outdoor Compressor
revolution
(rps)
High
38
High
50
High
67
High
78
Outdoor Compressor
revolution
(rps)
High
54
High
70
High
78
High
90
Connecting
piping
(m)
5.0
Connecting
piping
(m)
5.0

Advertisement

Table of Contents
loading

Table of Contents