Toshiba RAS-B07G3KVSG-E Service Manual page 35

Indoor/outdoor unit, r32 or r410a inverter
Hide thumbs Also See for RAS-B07G3KVSG-E:
Table of Contents

Advertisement

Item
2. Indoor fan
motor control
Fan speed
Mode
level
Cool
Heat
WF
UH
WE
UH
H
WD
H
M+
WC
M+
WB
M
WA
M
W9
L+
W8
L+
L
W7
L
L-
W6
L-
W5
UL
UL
W4
W3
SUL
W2
SUL
W1
Fan speed
Mode
level
Cool
Heat
WF
UH
WE
UH
H
WD
H
M+
WC
M+
WB
M
WA
M
W9
L+
W8
L+
L
W7
L
L-
W6
L-
W5
UL
UL
W4
W3
SUL
W2
SUL
W1
Operation flow and applicable data, etc.
(Table 1) Indoor fan air flow rate
RAS-B07,B10G3KVSG-E / RAS-B07, B10G3KVSGB-E
Cooling
Dry
Fan speed
Air flow rate
3
(rpm)
(m
/h)
1030
720
1030
720
UH
980
660
H
880
578
M+
800
540
M
700
444
650
394
L+
630
374
550
312
L
530
297
L-
520
290
UL
510
284
SUL/SL-
510
284
500
280
500
280
RAS-B16G3KVSG-E, RAS-B16G3KVSGB-E
Cooling
Dry
Fan speed Air flow rate Fan speed Air flow rate
3
(rpm)
(m
/h)
1120
804
1120
804
UH
1070
750
H
1020
702
M+
900
618
M
800
540
750
486
L+
700
534
600
360
L
590
350
L-
540
305
UL
540
305
SUL/SL-
530
297
520
290
500
280
RAS-B13G3KVSG-E, RAS-B13G3KVSGB-E
Heating
Fan speed
Air flow rate
Fan speed Air flow rate
3
(rpm)
(rpm)
(m
/h)
980
660
1100
980
660
1100
900
618
1050
800
540
1000
740
460
900
700
444
800
650
394
650
570
328
630
550
312
580
530
297
530
520
290
520
510
284
510
510
284
510
510
284
500
500
280
500
Heating
3
(rpm)
(m
/h)
1080
768
1080
768
1030
720
900
618
800
540
750
486
700
534
600
360
580
342
550
312
540
305
530
297
520
290
520
290
500
280
- 35 -
Description
Cooling
Heating
Fan speed Air flow rate
3
(rpm)
(m
/h)
(m
788
1050
788
1050
732
1000
688
900
618
800
540
700
394
650
374
580
342
550
297
530
290
520
284
510
284
510
280
510
280
500
3
/h)
732
732
668
618
540
444
394
342
312
297
290
284
284
284
280

Advertisement

Table of Contents
loading

Table of Contents