9-3-2. How to Set the Auto Restart Function

To set the auto restart function, proceed as follows:
The power supply to the unit must be on ; the function will not set if the power is off.
Press the [RESET] button located in the center of the front panel continuously for three seconds.
The unit receives the signal and beeps three times.
The unit then restarts operating automatically in the event of power supply being accidentally shut down.
• When the system is on stand-by (not operating)
Operation
Press [RESET] button for more than
three seconds. (Less than 10 seconds)
• When the system is operating
Operation
Press [RESET] button for more than
three seconds. (Less than 10 seconds)

9-3-3. Power Failure During Timer Operation

When the unit is turned off because of power failure during timer operation, the timer operation is can-celled. In
that case, set the timer operation again.
NOTE :
The Daily Timer is reset while a command signal can be received from the remote controller even if it stopped
due to a power failure.
The unit is on standby.
The unit starts to operate.
After approx. three seconds,
The unit beeps three times and continues to operate.
If the unit is not required to operate at this time, press [RESET]
button once more or use the remote controller to turn it off.
The unit is in operation.
The unit stops operating.
After approx. three seconds,
The unit beeps three times.
If the unit is required to operate at this time, press [RESET] button
once more or use the remote controller to turn it on.