Daikin Altherma EBLQ011CAV3 Service Manual page 68

Monobloc
Hide thumbs Also See for Altherma EBLQ011CAV3:
Table of Contents

Advertisement

2 Components
a
a
a
Latch
b
Wire terminal mounting plate
c
Wire terminal LB
d
Wire terminal NB
e
Faston connector with orange wire (+)
f
Faston connector with grey wire (-)
g
Tie strap
h
Red and blue wiring
i
Cable guide
j
Compressor wiring
k
Connector X205A
l
Connector X9A
3 Turn over the wire terminal mounting plate.
4 Disconnect the wire terminals LB and NB from the main PCB.
5 Disconnect the 2 Faston connectors.
6 Cut the tie 2 straps.
7 Remove the red and blue wiring from the cable guides.
8 Remove the compressor wiring from the cable guides.
9 Disconnect the connectors X205A and X9A.
10 Insert 2 flathead screwdrivers in the slots and unlatch the upper
and lower assemblies.
Service manual
68
b
g
i
h
i
j
g
k
l
k
i
a
Slot
b
Upper assembly
c
Lower assembly
11 Slightly lift the upper assembly and slide it to the right to release
the 3 hooks.
EBLQ+EDLQ011~016CAV3+W1 + EBLQ+EDLQ011~016CA3V3+W1
+ EK(2)CB07CAV3 + EKMBUHCA3V3+9W1
e
f
d
c
a
a
c
b
Daikin Altherma – Monobloc
ESIE18-04 – 2019.02

Advertisement

Table of Contents
loading

Table of Contents