Daikin Altherma EBLQ014CAV3 Installation Manual

Daikin Altherma EBLQ014CAV3 Installation Manual

Low temperature monobloc
Hide thumbs Also See for Altherma EBLQ014CAV3:
Table of Contents

Advertisement

Installation manual
Daikin Altherma low temperature monobloc
EBLQ011CAV3
EBLQ014CAV3
EBLQ016CAV3
EBLQ011CAW1
EBLQ014CAW1
EBLQ016CAW1
EDLQ011CAV3
EDLQ014CAV3
EDLQ016CAV3
EDLQ011CAW1
Installation manual
EDLQ014CAW1
English
Daikin Altherma low temperature monobloc
EDLQ016CAW1

Advertisement

Table of Contents
loading

Summary of Contents for Daikin Altherma EBLQ014CAV3

  • Page 1: To Remove The Accessories From The Outdoor Unit

    Installation manual Daikin Altherma low temperature monobloc EBLQ011CAV3 EBLQ014CAV3 EBLQ016CAV3 EBLQ011CAW1 EBLQ014CAW1 EBLQ016CAW1 EDLQ011CAV3 EDLQ014CAV3 EDLQ016CAV3 EDLQ011CAW1 Installation manual EDLQ014CAW1 English Daikin Altherma low temperature monobloc EDLQ016CAW1...
  • Page 2 (mm) † A, B, C — ≥500 ≥250 ≥400 ≥100 ≥150 A, B, C, E — ≥500 ≥250 ≥400 ≥150 ≥1000 ≤500 ≥150 — ≥500 ≥150 — D, E ≥500 ≥1000 ≤500 ≥150 B, D <H ≥250 ≥400 ≥500 ≥150 B, D, E <H ≥250...
  • Page 3 3PW57792-15J...
  • Page 4: Table Of Contents

    Daikin website (publicly accessible). 4.2.4 To prevent the outdoor unit from falling over ....Connecting the water piping............▪ The full set of latest technical data is available on the Daikin 4.3.1 To connect the water piping........extranet (authentication required).
  • Page 5: Preparation

    Use the following graph to determine the maximum water volume for diffusion tight according to DIN  4726. The diffusion of the calculated pre-pressure. oxygen into the piping can lead to excessive corrosion. EBLQ+EDLQ011~016CAV3+W1 Installation manual Daikin Altherma low temperature monobloc 4P522031-1 – 2018.01...
  • Page 6: Preparing Electrical Wiring

    More technical specifications of the different connections test (check that the user interface does NOT display error are indicated on the inside of the outdoor unit. 7H). Installation manual EBLQ+EDLQ011~016CAV3+W1 Daikin Altherma low temperature monobloc 4P522031-1 – 2018.01...
  • Page 7: Installation

    Prepare 6 sets of anchor bolts, nuts and washers (field supply) as When providing drainage, therefore make sure to cover the entire follows: unit. EBLQ+EDLQ011~016CAV3+W1 Installation manual Daikin Altherma low temperature monobloc 4P522031-1 – 2018.01...
  • Page 8: To Prevent The Outdoor Unit From Falling Over

    2 Place the 2 cables over the outdoor unit. 3 Insert a rubber sheet between the cables and the outdoor unit to prevent the cables from scratching the paint (field supply). Installation manual EBLQ+EDLQ011~016CAV3+W1 Daikin Altherma low temperature monobloc 4P522031-1 – 2018.01...
  • Page 9: To Connect The Water Piping To The Backup Heater

    ▪ Protection against freezing: the glycol will prevent the up inside the hose. liquid inside the piping from freezing. Lowest expected Prevent from Prevent from outdoor bursting freezing temperature –5°C –10°C –15°C –20°C — –25°C — EBLQ+EDLQ011~016CAV3+W1 Installation manual Daikin Altherma low temperature monobloc 4P522031-1 – 2018.01...
  • Page 10: To Fill The Water Circuit

    7 Repeat steps 5 and 6 until no more air is purged and there are no more pressure drops. ▪ Remote outdoor sensor (option) 8 Close the drain and fill valve. 9 Disconnect the water supply hose from the drain and fill valve. Installation manual EBLQ+EDLQ011~016CAV3+W1 Daikin Altherma low temperature monobloc 4P522031-1 – 2018.01...
  • Page 11: To Connect The Main Power Supply

    When installing field supply or option cables, foresee sufficient cable length. This will make it possible to remove/ reposition the switch box and gain access to other components during service. EBLQ+EDLQ011~016CAV3+W1 Installation manual Daikin Altherma low temperature monobloc 4P522031-1 – 2018.01...
  • Page 12: To Connect The Shut-Off Valve

    2 Connect the cable of the domestic hot water pump to the bottom side of control box terminals X8M/8+9. 1× 1× Notch this part for the wiring to pass through with nippers etc. Installation manual EBLQ+EDLQ011~016CAV3+W1 Daikin Altherma low temperature monobloc 4P522031-1 – 2018.01...
  • Page 13: Configuration

    > Information > User permission level. ▪ "To access the installer settings" on page 13 3 Press for more than 4 seconds. ▪ "5.3 Menu structure: Overview installer settings" on page 20 Result: is displayed on the home pages. EBLQ+EDLQ011~016CAV3+W1 Installation manual Daikin Altherma low temperature monobloc 4P522031-1 – 2018.01...
  • Page 14: To Copy The System Settings From The First To The Second User Interface

    (languages, schedules etc.) will be synchronised from the selected source user interface to the other one. Installer settings The system will restart. Cancel Confirm Adjust Installation manual EBLQ+EDLQ011~016CAV3+W1 Daikin Altherma low temperature monobloc 4P522031-1 – 2018.01...
  • Page 15: To Copy The Language Set From The First To The Second User Interface

    4 After configuration, select Confirm layout and press Confirm layout Please confirm the system layout. The system will restart and will be ready for first startup. Cancel Confirm Adjust EBLQ+EDLQ011~016CAV3+W1 Installation manual Daikin Altherma low temperature monobloc 4P522031-1 – 2018.01...
  • Page 16: Quick Wizard: Options

    ▪ 4 (3PN,(1/2)): 6 kW 3N~ 400 V (*9W) ▪ 2: N/A ▪ 5 (3PN,(1/1+2)): 9  kW 3N~  400  V If there are two zones (main (*9W) +additional), then only Thermo ON/OFF is possible. Installation manual EBLQ+EDLQ011~016CAV3+W1 Daikin Altherma low temperature monobloc 4P522031-1 – 2018.01...
  • Page 17: Quick Wizard: Capacities (Energy Metering)

    ▪ 3 (WD/scheduled): Weather- ▪ 1 (Yes) dependent + scheduled (only for leaving water temperature control) 5.2.4 Quick wizard: Capacities (energy metering) Code Description [A.2.3.1] [6-02] Booster heater capacity [kW] EBLQ+EDLQ011~016CAV3+W1 Installation manual Daikin Altherma low temperature monobloc 4P522031-1 – 2018.01...
  • Page 18: Domestic Hot Water Control

    2, but between the scheduled heatup and more economic operation. cycles, reheat operation is allowed. ▪ 2 (Scheduled only): The domestic hot water tank can ONLY be heated according to a schedule. Installation manual EBLQ+EDLQ011~016CAV3+W1 Daikin Altherma low temperature monobloc 4P522031-1 – 2018.01...
  • Page 19: Contact/Helpdesk Number

    [6‑0D]=0 ([A.4.1] Domestic hot water Type=Reheat only) in case of a domestic hot water tank without an internal booster heater. EBLQ+EDLQ011~016CAV3+W1 Installation manual Daikin Altherma low temperature monobloc 4P522031-1 – 2018.01...
  • Page 20: Menu Structure: Overview Installer Settings

    Forced pump OFF Emergency [A.7] Commissioning Test run UFH screed dryout Air purge Actuator test run INFORMATION Depending on the selected installer settings and unit type, settings will be visible/invisible. Installation manual EBLQ+EDLQ011~016CAV3+W1 Daikin Altherma low temperature monobloc 4P522031-1 – 2018.01...
  • Page 21: Commissioning

    The shut-off valves are properly installed and fully open. fluid is NOT collected, it might drip on internal components and damage the unit. The pressure relief valve purges water when opened. EBLQ+EDLQ011~016CAV3+W1 Installation manual Daikin Altherma low temperature monobloc 4P522031-1 – 2018.01...
  • Page 22: To Perform A Test Run

    Possible actuator test runs make sure the following is clear for the user: ▪ Fill in the installer setting table (in the operation manual) with the ▪ Booster heater test actual settings. Installation manual EBLQ+EDLQ011~016CAV3+W1 Daikin Altherma low temperature monobloc 4P522031-1 – 2018.01...
  • Page 23: About Locking And Unlocking

    Technical data A subset of the latest technical data is available on the regional Daikin website (publicly accessible). The full set of latest technical data is available on the Daikin extranet (authentication required).
  • Page 24: Wiring Diagram: Outdoor Unit

    Switching power supply only) A4P (V3 only) Printed circuit board (communication) Q1DI Earth leakage circuit breaker (30 mA) BS1~BS4 (A2P) Push-button switch R1, R2 (A1P) (V3 Resistor C1~C4 (A1P)(V3 Capacitor only) only) Installation manual EBLQ+EDLQ011~016CAV3+W1 Daikin Altherma low temperature monobloc 4P522031-1 – 2018.01...
  • Page 25 Overcurrent fuse booster heater Main PCB F2U (A4P) Fuse T 2 A 250 V for 3-way valve Current loop PCB Relay for heating EBLQ+EDLQ011~016CAV3+W1 Installation manual Daikin Altherma low temperature monobloc 4P522031-1 – 2018.01...
  • Page 26 F1T, F2T Thermal fuse backup heater S5P-S6P # Electrical meters Fuse T 5 A 500 V backup heater X*A (A4P) Connector option Terminal strip Contactor backup heater (step 1) Optional Field supply Installation manual EBLQ+EDLQ011~016CAV3+W1 Daikin Altherma low temperature monobloc 4P522031-1 – 2018.01...
  • Page 27 3 core Control box power supply: 230 V + earth X1M: L-N-PE X1M: L-N-PE 2 core 230 V External indoor thermistor X2M: 1a-2a Power supply signal Only for KRCS01-1 4D115044-1 EBLQ+EDLQ011~016CAV3+W1 Installation manual Daikin Altherma low temperature monobloc 4P522031-1 – 2018.01...
  • Page 28 4P522031-1 0000000B 4P522031-1 2018.01...