Daikin Altherma EBLQ011CAV3 Service Manual page 114

Monobloc
Hide thumbs Also See for Altherma EBLQ011CAV3:
Table of Contents

Advertisement

5 Technical data
English
F1U
F1U (A4P)
F2B
*
F2U (A4P)
K1A
K1
*
K2A
K2
*
K3M
*
M2P
# Domestic hot water pump
M2S
# Shut-off valve
M3S
M4S
*
PC (A7P)
Q2L
*
Q5DI, Q6DI
R1H (A3P)
*
R1T (A3P)
*
R1T (A5P)
R2T
*
R5T
*
S1S
# Preferential kWh rate power
STB
*
X*A (A4P)
X*M
*:
Optional
#:
Field supply
Control box option: backup heater
English
BUH option
Control box
Only for ***
E1H
E2H
E3H
F1B
*
F1T, F2T
*
Service manual
114
Translation
Fuse T 5 A 500 V
Fuse T 2 A 250 V
Overcurrent fuse booster heater
Fuse T 2 A 250 V for 3-way valve
Relay for heating
Terminal strip
Relay for cooling
Booster heater
Contactor booster heater
3-way valve for domestic hot
water
Valve kit
Power circuit
Thermal protector booster heater
Earth leakage circuit breaker
Humidity sensor
Ambient sensor On/OFF
thermostat
Ambient sensor user interface
External indoor floor/ambient
thermistor
Domestic hot water thermistor
supply contact
Thermal protector booster heater
Connector
Terminal strip
Translation
Backup heater option
Control box
Only for ***
Backup heater element (1 kW)
Backup heater element (2 kW)
Backup heater element
Overcurrent fuse backup heater
Thermal fuse backup heater
English
F1U
K1M
*
K1R
*
K2M
*
K2R
*
K5M
*
Q1DI
# Earth leakage circuit breaker
Q1L
*
R2T
*
X*M
*:
Optional
#:
Field supply
Control box option: option box
English
Alarm output
Control box
Electric pulse meter inputs: 5 V
DC pulse detection (voltage
supplied by PCB)
Ext. heat source
External indoor ambient sensor
option
Indoor
Max. load
Max. voltage
Min. load
Option box
ON
OFF
A4P
DS1 (A4P)
F1U (A4P)
F2U (A4P)
R6T
*
S5P-S6P
# Electrical meters
X*A (A4P)
X*M
*:
Optional
#:
Field supply
EBLQ+EDLQ011~016CAV3+W1 + EBLQ+EDLQ011~016CA3V3+W1
+ EK(2)CB07CAV3 + EKMBUHCA3V3+9W1
Translation
Fuse T 5 A 500 V backup heater
option
Contactor backup heater (step 1)
Relay backup heater (step 1)
Contactor backup heater (step 2)
(only for *9W)
Relay backup heater (step 2)
(only for *9W)
Safety contactor backup heater
(only for *9W)
Thermal protector backup heater
Outlet backup heater thermistor
Terminal strip
Translation
Alarm output
Control box
Electric pulse meter inputs:
5 V DC pulse detection (voltage
supplied by PCB)
External heat source
External indoor ambient sensor
option
Indoor
Maximum load
Maximum voltage
Minimum load
Option box
ON
OFF
Extension PCB (control, optional)
DIP switch
Fuse T 2 A 250 V
Fuse T 2 A 250 V for 3-way valve
External indoor ambient sensor
option
Connector
Terminal strip
Daikin Altherma – Monobloc
ESIE18-04 – 2019.02

Advertisement

Table of Contents
loading