Function Code; Function Name; Setting Range And Definition; Default Setting - Veichi SI23 Manual

Solar pump
Hide thumbs Also See for SI23:
Table of Contents

Advertisement

Sudden voltage
F21.49(0x5531)
increase threshold
F21.50(0x5532)
Reserved
F21.51(0x5533)
Reserved
F21.52(0x5534)
Reserved
F21.53(0x5535)
Functional selection
Times of Inermittent
F21.54(0x5536)
Operation
Start time of
F21.55(0x5537)
Inermittent Operation
Stop time of
F21.56(0x5538)
Inermittent Operation
Pump Clean
F21.57(0x5539)
Frequency
F21.58(0x553A)
FWD Running Time
F21.59(0x553B)
REV Running Time
F21.60(0x553C)
Cycle Times
F21.61(0x553D)
Power Limitation
F21.62(0x553E)
Power Limitation Kp
F21.63(0x553F)
Power Limitation Ki
● Photovoltaic Pump Special Monitor Parameters

Function code

Function name

C04.00(0x2500)
Frequency reference
C04.01(0x2501)
Output frequency
C04.02(0x2502)
Output current
C04.03(0x2503)
Cycle Times 1
C04.04(0x2504)
Cycle Times 2
C04.05(0x2505)
Reserved
C04.06(0x2506)
Operation Time
C04.07(0x2507)
Stop Time
C04.08(0x2508)
Reserved
C04.09(0x2509)
Reserved
0.0%~20.0%
LED0: Inermittent Operation Storage
0:None; 1:Storaged
LED00:Stop Mode When Alarm
0:Slow down
1:Free stop
LED000:Reserved
LED0000:Reserved
0~1000
0min~3000min
0min~3000min
0.00Hz~300.00Hz
0s~3000s
0s~3000s
0~60
0.0~1000.0
0.0~100.0
0.0~100.0
Setting range
and definition
41
SI23 Solar Pump VFD Manual
5.0%
0000
0
0
0
25.00Hz
30s
30s
5
0.0
1.0
1.0

Default setting

0.01Hz
Read only
0.01Hz
Read only
0.1A
Read only
Read only
Read only
Read only
1min
Read only
1min
Read only
Read only
Read only

Advertisement

Table of Contents
loading

Table of Contents