Veichi SI23 Manual page 40

Solar pump
Hide thumbs Also See for SI23:
Table of Contents

Advertisement

Go to sleep mode
F21.11(0x550B)
voltage
Wake up restore
F21.12(0x550C)
voltage
Sleeping stop restore
F21.13(0x550D)
waiting time
Low speed protection
F21.14(0x550E)
detect frequency
Low speed
F21.15(0x550F)
protection detect time
Low speed protection
F21.16(0x5510)
restore working time
Dry run protection
F21.17(0x5511)
detect current
Dry run protection
F21.18(0x5512)
detect time
Dry run auto restore
F21.19(0x5513)
working time
Over current point
F21.20(0x5514)
setting
Over current
F21.21(0x5515)
protection detect time
Over current
F21.22(0x5516)
protection auto
restore working time
Input minimum power
F21.23(0x5517)
protection power point
setting
Minimum power
F21.24(0x5518)
protection detect time
Minimum power
F21.25(0x5519)
protection auto
restore working time
Fault alarm restore
F21.26(0x551A)
mode
0V~1000V
0V~1000V
0.0s~3000.0s
0.00Hz~300.00Hz
0.0s~3000.0s
0.0s~3000.0s
0.0A~999.9A
0.0s~3000.0s
0.0s~3000.0s
0.0A~999.9A
0.0s~3000.0s
0.0s~3000.0s
0.00kW~650.00kW
0.0s~3000.0s
0.0s~3000.0s
0:Auto reset;1:Reset by manual
LED0:Low speed protection
LED1:Dry run
LED2:Over current protection
LED3: Minimum power protection
39
SI23 Solar Pump VFD Manual
0V
400V
10.0s
10.00Hz
10.0s
10.0s
0.0A
10.0s
10.0s
0.0A
10.0s
10.0s
0.00kW
10.0s
10.0s
0000