I/O Terminals
Parameter
Function
(address)
Description
Terminal X1
F05.00(0x0500)
function
selection
Terminal X2
F05.01(0x0501)
function
selection
Terminal X3
F05.02(0x0502)
function
selection
Terminal X4
F05.03(0x0503)
function
selection
F05.50(0x0532)
AI lower limit
AI lower limit
F05.51(0x0533)
corresponding
setting
F05.52(0x0534)
AI upper limit
AI upper limit
F05.53(0x0535)
corresponding
setting
AO output mode
F06.00(0x0600)
selection
F06.01(0x0601)
AO output
selection
Range of settings and definition
V/F SVC FVC
See the function of terminal X for details.
V/F SVC FVC
See the function of terminal X for details.
V/F SVC FVC
See the function of terminal X for details.
V/F SVC FVC
See the function of terminal X for details.
V/F SVC FVC
Define the signal received by the terminal. The
voltage signal below this value is processed by
the limit value.
V/F SVC FVC
Set the percentage of the corresponding set
value
V/F SVC FVC
Define the signal received by the terminal. The
voltage signal above this value is processed
according to the upper limit value.
V/F SVC FVC
Set the percentage of the corresponding set
value.
V/F SVC
0: 0V~10V
1: 4.00mA~20.00mA
2: 0.00mA~20.00mA
3: Reserved
4: Reserved
V/F SVC FVC
0: Given frequency
1: Output frequency
2: Output current
3: Input voltage
4: Output voltage
5: Mechanical speed
29
SI23 Solar Pump VFD Manual
Factory default
Notes
(setting range)
1
(0~63)
2
(0~63)
4
(0~63)
8
(0~63)
0.0%
(0.0%~100.0%)
0.0%
(-100.0%~
100.0%)
100.00%
(0.00%~
100.00%)
100.00%
(0.00%~
100.00%)
0
(0~4)
0
(0~19)