Veichi SI23 Manual page 41

Solar pump
Hide thumbs Also See for SI23:
Table of Contents

Advertisement

Water fulfilled detect
F21.27(0x551B)
time
Water fulfilled restore
F21.28(0x551C)
time
F21.29(0x551D)
reserve
DC current revise
F21.30(0x551E)
offset
DC current revise
F21.31(0x551F)
proportion gain
F21.32(0x5520)
Power curve point 0
F21.33(0x5521)
Power curve point 1
F21.34(0x5522)
Power curve point 2
F21.35(0x5523)
Power curve point 3
F21.36(0x5524)
Power curve point 4
F21.37(0x5525)
Flow curve point 0
F21.38(0x5526)
Flow curve point 1
F21.39(0x5527)
Flow curve point 2
F21.40(0x5528)
Flow curve point 3
F21.41(0x5529)
Flow curve point 4
Flow calculating
F21.42(0x552A)
revise offset
Flow calculating
F21.43(0x552B)
revise gain
Power per day/
F21.44(0x552C)
generated power per
day reset period
F21.45(0x552D)
Reserved
Photovoltaic pump
F21.46(0x552E)
function selection 1
Fast frequency falling
F21.47(0x552F)
threshold
Constant torque
F21.48(0x5530)
frequency limit
coefficient
0.0s~3000.0s
0.0s~3000.0s
0.00A~99.99A
0.0%~999.9%
0.00kW~99.99kW
0.00kW~99.99kW
0.00kW~99.99kW
0.00kW~99.99kW
0.00kW~99.99kW
0.0m³/h~999.9m³/h
0.0m³/h~999.9m³/h
0.0m³/h~999.9m³/h
0.0m³/h~999.9m³/h
0.0m³/h~999.9m³/h
0.0m³~999.9m³
0.0%~999.9%
0.0h~24.0h
0:Invalid
1:Valid
LED0:Constant torque frequency limit
selection
LED1:Reserved
LED2:Voltage rising update Voc voltage
LED3: Fast frequency falling function
3.0%~15.0%
80.0%~150.0%
40
SI23 Solar Pump VFD Manual
10.0s
10.0s
0.01A
100.0%
0.50kW
1.00kW
1.50kW
2.00kW
2.50kW
0.0m³/h
5.0m³/h
10.0m³/h
15.0m³/h
20.0m³/h
0.0m³
100.0%
7.0h
1100H
5.0%
100.0%