Output terminal
F06.20(0x0614)
polarity selection
Output terminal
F06.21(0x0615)
Y
Relay 1 output
F06.22(0x0616)
(TA-TB-TC)
● Start/Stop Control
Parameter
Function
(address)
Description
Direction of
F07.05(0x0705)
rotation
6: Given torque
7: Output torque
8: PID given
9: PID feedback amount
10: Output power
11: Bus voltage
12: VS input value
13: AI input value
14: AS input value
15: PUL input value
16: Module temperature 1
17: Module temperature 2
18: 485 communication given
19: Virtual terminal vY1
V/F SVC FVC
0: Positive polarity 1: Negative polarity
LED "0" digit: Y terminal
LED "00" digit: Relay output terminal 1
LED "000" digit: Reserved
LED "0000" digit: Reserved
V/F SVC FVC
See terminal Y function
V/F SVC FVC
See terminal Y function
Range of settings and definition
V/F SVC FVC
LED "0" digit: Reverse the running direction.
0: The direction is unchanged
1: Direction reversal
LED "00" digit: No direction of operation.
0: Allow forward and reverse commands
1: Only forward commands are allowed
2: Only reverse command is allowed
LED "000" digit: Frequency Control Command
Direction.
0: The frequency control direction is invalid.
1: Frequency control direction is valid
LED "0000" digit: Reserved.
30
SI23 Solar Pump VFD Manual
0000
(0000~1111)
1
(0~63)
4
(0~63)
Factory default
Notes
(setting range)
0000