Veichi SI23 Manual page 35

Solar pump
Hide thumbs Also See for SI23:
Table of Contents

Advertisement

keyboard
Parameter 4
showed up on
F11.14(0x0B0E)
first line of the
keyboard
Keyboard
F11.20(0x0B14)
display item
settings
Communication Parameters
Parameter
Function
(address)
Description
Master-slave
F12.00(0x0C00)
choice
Modbus
F12.01(0x0C01)
communication
address
Modbus data
F12.03(0x0C03)
format
00~63.
LED "000" and "0000" digit: Monitoring
parameter number Cxx.yy xx setting
00~07.
V / F SVC
LED "0" and "00" digit: Monitor parameter
number Cxx.yy YY setting
00~63.
LED "000" and "0000" digit: Monitoring
parameter number Cxx.yy XX setting
00~07.
V/F SVC FVC
LED "0" digit: Output frequency display
selection.
0: Target frequency
1: Operating frequency
LED "00" digit: Reserved.
0: Invalid
1: Active power to remove stator resistance loss
LED "000" digit: Power Display Dimensions.
0: Power display percentage (%)
1: Power display kilowatt (kW)
LED "0000" digit: Reserved
Range of settings and definition
V/F SVC FVC
0: Slave
1: Host
V/F SVC FVC
V/F SVC FVC
0: (N, 8, 1) no parity,
Data bits: 8,
Stop position: 1
1: (E, 8, 1) even parity,
Data bits: 8,
Stop position: 1
2: (O, 8, 1) odd parity,
Data bits: 8,
Stop position: 1
34
SI23 Solar Pump VFD Manual
0011
(0000~0763)
0000
(0000~1111)
Factory default
Notes
(setting range)
0
(0~1)
1
(1~247)
0
(0~5)