Solar Pump Controller Wiring - Veichi SI23 Manual

Solar pump
Hide thumbs Also See for SI23:
Table of Contents

Advertisement

2.2 Solar Pump Controller Wiring

Standard Connection Diagram
PV modules
(FWD)
(REV)
(Water full detection alarm)
(Water full detection reset)
(Free stop)
RS485 Communication
Analog Voltage/Current Input 1
Analog Voltage/Current Input 2
Note :
1 +10V Max.Output:50mA
Note: 1.When connect solar panel, please connect PV+/PV-.
2.The communication interface of the PCE is considered as DVC A. The external signal communication interface is
considered as SELV. The compatibility shall be considered when the communication interfaces are connected.
Auxiliary Terminal Output Capacity
Terminal
10V auxiliary power supply output, constitutes loop with GND.
+10V
A0
Analog monitor output, constitutes loop with GND.
+24V
24V auxiliary power supply output, constitutes loop with COM.
Collector open circuit output; can set the action-object by program.
Y
TA/TB/TC
Passive connector output; can set the action-object by program.
DC breaker
PV+
PV-
+24V
GND
X1
X2
X3
X4
X5
COM
A+
120Ω
B-
+10V
AI1
AI2
GND
Function Definition
14
SI23 Solar Pump VFD Manual
Output Reactor
U
VFD
V
W
E
TA
Coil
TB
TC
+24V
Y
COM
Note :
1 +24V Max. Output:DC24V/100mA
2 Y Max. Output:DC24V/50mA
10
_
mA
-
+
AO1
GND
50mA
Max output 2mA as frequency,
voltage signal
100mA
DC24V/50mA
5A/30VDC
U
V
M
~
W
(The grounding resistance is
less than10Ω )
MAX Output:
5A/30VDC
Coil
Max Output

Advertisement