Veichi SI23 Manual page 34

Solar pump
Hide thumbs Also See for SI23:
Table of Contents

Advertisement

Failure
F10.50(0x0A32)
self-recovery
Failure
F10.51(0x0A33)
self-recovery
interval
Numbers of
F10.52(0x0A34)
failures
recovered
Operation Parameters
Parameter
Function
(address)
Description
Key lock
F11.00(0x0B00)
selection
Key lock
F11.01(0x0B01)
password
Parameter 1
showed up on
F11.11(0x0B0B)
first line of the
keyboard
Parameter 2
showed up on
F11.12(0x0B0C)
first line of the
keyboard
Parameter 3
F11.13(0x0B0D)
showed up on
first line of the
V/F SVC FVC
Set the number of fault self-recovery that is
allowed to be performed.
Note: A value of 0 indicates that the fault
self-recovery function is turned off; otherwise it
indicates that the function is enabled.
V/F SVC FVC
Set the waiting time before the VFD resets to
the time before each reset.
V/F SVC FVC
Indicates the number of self-recovery faults that
have been performed. This parameter is a
read-only parameter.
Range of settings and definition
V/F SVC FVC
0: Not locked.
1: Keyboard function parameter modification
lock.
2: Function parameters and non-start stop
button lock.
3: Function parameters and button full lock.
V/F SVC
V/F SVC FVC
LED "0" and "00" digit: Setting yy setting in
monitoring parameter number Cxx.yy
00~63.
LED "000" and "0000" digit: Monitoring
parameter number Cxx.yy xx setting
00~07.
V/F SVC FVC
LED "0" and "00" digit: Setting yy setting in
monitoring parameter number Cxx.yy
00~63.
LED "000" and "0000" digit: Monitoring
parameter number Cxx.yy xx setting
00~07.
V/F SVC FVC
LED "0" and "00" digit: Setting yy setting in
monitoring parameter number Cxx.yy
33
SI23 Solar Pump VFD Manual
0
(0~10)
1.0s
(0.0s~100.0s)
0
Factory default
Notes
(setting range)
0
(0~3)
0
(0~65535)
0000
(0000~0763)
0001
(0000~0763)
0002
(0000~0763)