Seco Smarc CSM-B79 User Manual page 47

Carrier board for smarc rel. 2.0 / 2.1 compliant modules
Table of Contents

Advertisement

Signal Description:
SATA_TX+/SATA_TX-: Serial ATA Transmit differential pair.
SATA_RX+/SATA_RX-: Serial ATA Receive differential pair.
SATA 7p M Connector
CN34
Pin
Signal
1
GND
2
SATA_TX-
3
SATA_TX+
4
GND
5
SATA_RX+
6
SATA_RX-
7
GND
3.3.9 S-ATA Power Connector
S-ATA Power Connector
CN37
Pin
Signal
1
+12V_RUN
2
GND
3
GND
4
+5V_RUN
CSM-B79
CSM-B79 User Manual - Rev. First Edition: 1.0 - Last Edition: 1.1 - Author: A.R - Reviewed by S.R. - Copyright © 2021 SECO S.p.A.
For the connection of external Mass Storage Devices, there is a standard male S-ATA connector, CN34.
®
Since SMARC
modules can manage only one S-ATA interface, then only one of the two connectors
(the SATA 7p M connector CN34 and the SATA M.2 SSD slot CN35) can work at a time.
Switching between the two connectors is automatic, and it is managed by the signal
SATA_M2_SELECT# available on SATA M.2 Slot CN35 (pin 69).
When M.2 SSD is not plugged, the SATA interface is redirected by default to the 7p M connector CN34.
Vice versa, when M.2 SSD is plugged, the SATA interface is redirected by default to SATA M.2 SSD slot CN35.
When both an M.2 SSD and a SATA Drive are plugged, the SATA interface is switched toward the M.2 slot.
A dedicated power connector, CN37, can be used to give supply to external Hard Disks (or Solid State
Disks) connected to the SATA male connector CN34.
The dedicated power connector is a 4-pin male connector, type MOLEX p/n 89400-0420 or equivalent,
with pinout shown in the table on the left.
Mating connector: MOLEX 87369-0400 crimp housing with MOLEX 51021 crimp terminals.
47

Advertisement