Specifications
Environmental
PXI-1000 User Manual
Table A-5. Environmental Specifications
Characteristic
Operating Temperature
Storage Temperature
Operating Relative
Humidity
Functional Shock
(Operating)
Operating Location
Random Vibration
(Operational)*
Random Vibration
(Non-Operational)*
EMC Emissions
EMC Immunity
Altitude
* Random vibration profiles were developed in accordance with MIL-T-28800E CLASS 3
and MIL-STD-810E Method 514 Test levels exceed those recommended in
MIL-STD-810E for Category 1 (Basic Transportation), Figures 514.4-1 through 514.4-3.
A-4
Description
0° to 50° C (fan in LO position)
0° to 55° C (fan in HI position)
–20° to 70° C
Maximum 80% for temperatures up to
31° C, decreasing linearly to 50% at 40° C
MIL-T-28800E CLASS 3, Half-Sine
Shock Pulse, 11 ms duration, 30 g peak
Indoor use
5 to 500 Hz, 0.31 g
RMS
10 to 500 Hz, 2.46 g
RMS
FCC Class A compliant and EN 55011
Group 1 Class A Compliant
Refer to DOC supplied with chassis for
compliance to relevant directives.
2 km (1.24 mi)