National Instruments PXI PXITM -1000 User Manual
National Instruments PXI PXITM -1000 User Manual

National Instruments PXI PXITM -1000 User Manual

National instruments pxi user manual pxitm -1000
Table of Contents

Advertisement

Quick Links

PXI
PXI
-1000 User Manual
PXI-1000 User Manual
January 1998 Edition
Part Number 321710B-01

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the PXI PXITM -1000 and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for National Instruments PXI PXITM -1000

  • Page 1 ™ -1000 User Manual PXI-1000 User Manual January 1998 Edition Part Number 321710B-01...
  • Page 2 Singapore 2265886, Spain 91 640 0085, Sweden 08 730 49 70, Switzerland 056 200 51 51, Taiwan 02 377 1200, United Kingdom 01635 523545 National Instruments Corporate Headquarters 6504 Bridge Point Parkway Austin, Texas 78730-5039 USA Tel: 512 794 0100 © Copyright 1997, 1998 National Instruments Corporation. All rights reserved.
  • Page 3: Important Information

    90 days from date of shipment, as evidenced by receipts or other documentation. National Instruments will, at its option, repair or replace software media that do not execute programming instructions if National Instruments receives notice of such defects during the warranty period.
  • Page 4 Notices to User: If necessary, consult National Instruments or an experienced radio/television technician for additional suggestions. The following booklet prepared by the FCC may also be helpful: Interference to Home Electronic Entertainment Equipment Handbook. This booklet is available from the U.S. Government Printing Office, Washington, DC 20402.
  • Page 5: For Your Safety

    Part Replacement—Only service this equipment with parts that are exact replacements, both electrically and mechanically. Contact National Instruments for replacement part information. Installation of parts with those that are not direct replacements may cause harm to personnel operating the mainframe. Furthermore, damage or fire may occur if replacement parts are unsuitable.
  • Page 6: Table Of Contents

    Connecting to AC Mains Power and Testing Power up ...2-3 Remote Power Monitoring and Inhibiting Interface...2-5 Installing PXI Modules ...2-6 Installing Filler Panels ...2-7 Using the Chassis Initialization File ...2-7 Chapter 3 Maintenance Service Interval ...3-1 Preparation ...3-1 © National Instruments Corporation PXI-1000 User Manual...
  • Page 7 PXI-1000 Dimensions... A-7 Tables Table 1-1. Power Cables ... 1-1 Table 2-1. Power Supply Voltages at Power Monitoring Connector (DB-9) ... 2-4 Table 2-2. DB-9 Connector Pinout... 2-5 Table 3-1. Troubleshooting ... 3-4 PXI-1000 User Manual viii © National Instruments Corporation...
  • Page 8 P2 (J2) Connector Pinout for the Star Trigger Slot ...B-5 Table B-5. P1 (J1) Connector Pinout for the Peripheral Slot ...B-6 Table B-6. P2 (J2) Connector Pinout for the Peripheral Slot ...B-7 © National Instruments Corporation Contents PXI-1000 User Manual...
  • Page 9: About This Manual

    Appendix B, Pinouts, describes the P1 and P2 connector pinouts for the PXI-1000 backplane. Appendix C, Customer Communication, contains forms you can use to request help from National Instruments or to comment on our products and manuals. Glossary lists abbreviations, acronyms, metric prefixes, mnemonics, symbols, and terms.
  • Page 10: Related Documentation

    • Customer Communication National Instruments wants to receive your comments on our products and manuals. We are interested in the applications you develop with our products, and we want to help if you have problems with them. To make it easy for you to contact us, this manual contains comment and configuration forms for you to complete.
  • Page 11: Getting Started

    What You Need to Get Started The PXI-1000 kit contains the following items: Standard 120 V (USA) Switzerland 220 V Australia 240 V © National Instruments Corporation PXI-1000 mainframe Filler panels Power cable (see Table 1-1) PXI-1000 User Manual Floppy disk with Chassis Initialization file, Table 1-1.
  • Page 12: Optional Equipment

    National Instruments. Optional Equipment An optional rack-mount kit is available from National Instruments. You can use this kit to install the PXI-1000 mainframe into a standard 19 in. (482 mm) instrument cabinet. Contact National Instruments to order the PXI-1000 rack-mount kit.
  • Page 13: Figure

    Figures 1-1 and 1-2 show some of the key features and components of the PXI-1000 mainframe. Figure 1-1 shows the front view of the PXI-1000 and Figure 1-2 shows the rear view. © National Instruments Corporation Selectable fan speed for maximum cooling or quiet operation Carrying handle for portability...
  • Page 14: Figure 1-1. Front View Of The Pxi-1000 Mainframe

    (Located in Slots 1-8) PXI-1000 User Manual 3 Optional Mounting Brackets 4 Removable Feet 5 Peripheral Slots Figure 1-1. Front View of the PXI-1000 Mainframe STANDBY ZABCDEF 6 Star Trigger Slot 7 System Controller Slot 8 Controller Expansion Slots © National Instruments Corporation...
  • Page 15: System Controller Slot

    Peripheral Slots There are seven peripheral slots including the Star Trigger controller slot. © National Instruments Corporation FAN SPEED DB-9 5 Chassis Ground Screw 6 Remote Power Status and Inhibit Connector Figure 1-2.
  • Page 16: Local Bus

    PXI peripheral modules. In other applications, one module can control carefully timed sequences of PXI-1000 User Manual Star Triggers Local Local PCI Arbitration and Clock Signals Figure 1-3. PXI Local Bus and Star Trigger Routing Local © National Instruments Corporation...
  • Page 17: System Reference Clock

    PXI_CLK10_IN pin on the P2 connector of the Star Trigger Slot. (See Table B-1, Controller this pin automatically disables the backplane’s 10 MHz source. © National Instruments Corporation P1 (J1) Connector Pinout for the System Slot, in Appendix B, Pinouts.) Sourcing an external clock on Chapter 1...
  • Page 18: Figure

    Keep other equipment a minimum of 3.0 in. (76.2 mm) away from the air inlets and outlets. © National Instruments Corporation For Your Safety section located at the beginning of this manual.
  • Page 19: Rack Mounting

    Rack Mounting Rack-mount applications require the optional rack-mount kit available from National Instruments. Refer to the instructions supplied with the rack-mount kit to install your PXI-1000 in an instrument rack. You may wish to remove the feet from your PXI-1000 when rack mounting. To do Note so, remove the two screws holding the feet in place.
  • Page 20: Connecting Safety Ground

    On/Off (Standby) switch on the front to power up and power down the backplane. © National Instruments Corporation Mainframe, for a diagram of the chassis grounding screw. To Connect a 16 AWG (1.3 mm) wire to the chassis grounding screw using a toothed grounding lug.
  • Page 21: Power Supply Voltages At Power Monitoring Connector (Db-9)

    Table 2-1. Power Supply Voltages at Power Monitoring Connector (DB-9) Supply +5 V +3.3 V +12 V –12 V 1, 9 Logic Ground Acceptable Voltage Range 4.75 to 5.25 V 3.135 to 3.465 V 11.4 to 12.6 V –12.6 to –11.4 V Troubleshooting the © National Instruments Corporation...
  • Page 22: Remote Power Monitoring And Inhibiting Interface

    (standby) switch, located on the front of the chassis, uses this inhibiting feature. For remote reset, connect a momentary switch between pin 5 and pin 1 (or pin 9). © National Instruments Corporation Chapter 2 Table 2-2. DB-9 Connector Pinout...
  • Page 23: Installing Pxi Modules

    Secure the module’s front panel to the mainframe using the module’s front-panel mounting screws. PXI-1000 Chassis PXI-8156 System Controller PXI Board Injector/Ejector Handle PXI-1000 User Manual Injector/Ejector Rail Figure 2-2. Installing PXI or CompactPCI Modules © National Instruments Corporation...
  • Page 24: Installing Filler Panels

    .ini file. The PXI-1000 chassis initialization file, the diskette for your PXI-1000. © National Instruments Corporation Figure 2-3. Injector/Ejector Handle Position during Module Insertion files, which consist of ASCII text. The system integrator can read the file, and configuration utilities and device drivers can also use this...
  • Page 25: Maintenance

    Always power-off the mainframe (using the main power switch on the rear of the mainframe) and disconnect the power cord before cleaning or servicing the mainframe. © National Instruments Corporation For Your Safety section at the beginning of this manual...
  • Page 26: Interior Cleaning

    Clean the fan filters by washing them in a mild soap solution and then vacuuming or blowing air through them. Rinse the filters with water and allow them to dry before reinstalling them on the mainframe. PXI-1000 User Manual © National Instruments Corporation...
  • Page 27: Resetting The Ac Mains Circuit Breaker

    Complete the following steps to reset the circuit breaker: If the circuit breaker trips again, complete the following steps: © National Instruments Corporation Turn the front panel (remote) power switch to the Standby position. Turn off the rear main power switch.
  • Page 28: Table

    (standby) power switch to the On position. Deactivate your system’s remote inhibiting control. Reset the circuit breaker. Refer to the Resetting the AC Mains Circuit Breaker section in this chapter. Contact National Instruments. What to Do © National Instruments Corporation...
  • Page 29: Table A-1. Ac Input Specifications

    Input Frequency Range Over-Current Protection Operating Current Line Regulation Efficiency Transient Response Power Disconnect © National Instruments Corporation Table A-1. AC Input Specifications Characteristic 90–264 VAC 47 to 63 Hz 10 A circuit breaker ± 0.5% over operating line range, all...
  • Page 30: Table A-2. Dc Output Specifications

    3.3 V clamps at 20% to 30% above output voltage 5 V, +12 V, and –12 V clamps at 10% to 20% above output voltage 90,000+ hr Replacement in under 5 minutes Description (Steady-State Current) 40 A 20 A © National Instruments Corporation...
  • Page 31: Table A-3. Cooling Specifications

    Exhaust Module Cooling Fan MTBF Power Supply/Fan Unit Safety Safety Characteristics © National Instruments Corporation Table A-3. Cooling Specifications Characteristic Slot cooling capacity in worst-case slot is 20 W with fan speed set to HI Forced air circulation (positive pressurization) via two 60 cfm fans with...
  • Page 32: Table A-5. Environmental Specifications

    5 to 500 Hz, 0.31 g 10 to 500 Hz, 2.46 g FCC Class A compliant and EN 55011 Group 1 Class A Compliant Refer to DOC supplied with chassis for compliance to relevant directives. 2 km (1.24 mi) Description © National Instruments Corporation...
  • Page 33: Table A-6. Backplane Specifications

    Backplane Size Backplane Bare-Board Material Backplane Connectors © National Instruments Corporation Table A-6. Backplane Specifications Characteristic 3U-sized; one system slot (with three system expansion slots) and seven peripheral slots. Compliant with IEEE 1101.10 mechanical packaging. PXI Specification Revision 1.0 compliant.
  • Page 34: Table A-7. Mechanical Specifications

    1.48 cm (.583 in.) in rear. 8.6 kg (19 lb.) 1.8 kg (4 lb.) Sheet Aluminum (5052-H32) and Cold Rolled Steel Unpainted Aluminum Conductive Clear Iridite Cold Rolled Steel Clear Chromate Zinc Plating Paint Polyurethane Enamel Description © National Instruments Corporation...
  • Page 35: Figure A-1. Pxi-1000 Dimensions

    Note that the front and rear chassis mounting holes (size M4) are symmetrical. STANDBY 7.00 in. 10.64 in. 14.90 in. 1.823 in. .78 in. 1.00 in. 3.541 in. 1.844 in. .71 in. Figure A-1. PXI-1000 Dimensions © National Instruments Corporation PXI-1000 User Manual...
  • Page 36 Table B-4 shows the P2 (J2) connector pinout for the Star Trigger slot. Table B-5 shows the P1 (J1) connector pinout for the peripheral slots. Table B-6 shows the P2 (J2) connector pinout for the peripheral slots. Note PXI signals are shown in boldface. © National Instruments Corporation PXI-1000 User Manual...
  • Page 37: Table B-1. P1 (J1) Connector Pinout For The System Controller Slot

    AD[20] IDSEL AD[23] V(I/O) AD[25] AD[29] AD[28] 3.3V BRSVP1B5 RST# V(I/O) INTP INTB# INTC# –12V TRST# +12V ACK64# AD[2] AD[5] C/BE[0]# AD[10] AD[13] C/BE[1]# PERR# LOCK# TRDY# C/BE[2]# AD[19] AD[22] AD[24] AD[27] AD[31] GNT# INTS INTD# © National Instruments Corporation...
  • Page 38: Table B-2. P2 (J2) Connector Pinout For The System Controller Slot

    PXI_TRIG3 PXI_TRIG2 PXI_TRIG1 PXI_BRSVA15 AD[35] AD[38] AD[42] AD[45] AD[49] AD[52] AD[56] AD[59] AD[63] C/BE[5]# V(I/O) CLK4 CLK2 CLK1 © National Instruments Corporation PXI_RSVB22 PXI_RSVC22 PXI_TRIG4 PXI_TRIG5 PRST# PXI_TRIG0 DEG# FAL# AD[34] AD[33] V(I/O) AD[41] AD[40] V(I/O) AD[48] AD[47] V(I/O) AD[55]...
  • Page 39: Table B-3. P1 (J1) Connector Pinout For The Star Trigger Slot

    BRSVP1B5 RST# V(I/O) INTB# INTC# –12V TRST# 3.3V AD[0] ACK64# AD[2] AD[6] AD[5] M66EN C/BE[0]# AD[11] AD[10] AD[13] C/BE[1]# PERR# STOP# LOCK# TRDY# C/BE[2]# AD[20] AD[19] AD[22] AD[25] AD[24] AD[27] AD[31] GNT# INTP INTS INTD# +12V © National Instruments Corporation...
  • Page 40: Table B-4. P2 (J2) Connector Pinout For The Star Trigger Slot

    PXI_TRIG3 PXI_TRIG2 PXI_TRIG1 PXI_BRSVA15 AD[35] AD[38] AD[42] AD[45] AD[49] AD[52] AD[56] AD[59] AD[63] C/BE[5]# V(I/O) PXI_LBR7 PXI_LBR11 PXI_STAR9 © National Instruments Corporation PXI_RSVB22 PXI_RSVC22 PXI_LBR1 PXI_LBR5 PXI_STAR0 PXI_STAR3 PXI_TRIG4 PXI_TRIG5 PRST# PXI_TRIG0 DEG# FAL# AD[34] AD[33] V(I/O) AD[41] AD[40] V(I/O)
  • Page 41: Table B-5. P1 (J1) Connector Pinout For The Peripheral Slot

    BRSVP1B5 RST# V(I/O) INTB# INTC# –12V TRST# 3.3V AD[0] ACK64# AD[2] AD[6] AD[5] M66EN C/BE[0]# AD[11] AD[10] AD[13] C/BE[1]# PERR# STOP# LOCK# TRDY# C/BE[2]# AD[20] AD[19] AD[22] AD[25] AD[24] AD[27] AD[31] GNT# INTP INTS INTD# +12V © National Instruments Corporation...
  • Page 42: Table B-6. P2 (J2) Connector Pinout For The Peripheral Slot

    PXI_TRIG3 PXI_TRIG2 PXI_TRIG1 PXI_BRSVA15 AD[35] AD[38] AD[42] AD[45] AD[49] AD[52] AD[56] AD[59] AD[63] C/BE[5]# V(I/O) PXI_LBR7 PXI_LBR11 PXI_LBL9 © National Instruments Corporation PXI_RSVB22 PXI_RSVC22 PXI_LBR1 PXI_LBR5 PXI_LBL0 PXI_LBL3 PXI_TRIG4 PXI_TRIG5 PRST# PXI_TRIG0 DEG# FAL# AD[34] AD[33] V(I/O) AD[41] AD[40] V(I/O)
  • Page 43: Customer Communication

    Electronic Services Bulletin Board Support National Instruments has BBS and FTP sites dedicated for 24-hour support with a collection of files and documents to answer most common customer questions. From these sites, you can also download the latest instrument drivers, updates, and example programs. For recorded instructions on how to use the bulletin board and FTP services and for BBS automated information, call 512 795 6990.
  • Page 44: Telephone And Fax Support

    Telephone and Fax Support National Instruments has branch offices all over the world. Use the list below to find the technical support number for your country. If there is no National Instruments office in your country, contact the source from which you purchased your software to obtain support.
  • Page 45: Technical Support Form

    National Instruments for technical support helps our applications engineers answer your questions more efficiently. If you are using any National Instruments hardware or software products related to this problem, include the configuration forms from their user manuals. Include additional pages if necessary.
  • Page 46 Complete a new copy of this form each time you revise your software or hardware configuration, and use this form as a reference for your current configuration. Completing this form accurately before contacting National Instruments for technical support helps our applications engineers answer your questions more efficiently.
  • Page 47: Other Products

    Other Products List and describe all devices installed in your mainframe. Slot Manufacturer, Description, and Function...
  • Page 48: Documentation Comment Form

    Documentation Comment Form National Instruments encourages you to comment on the documentation supplied with our products. This information helps us provide quality products to meet your needs. Title: ™ -1000 User Manual Edition Date: January 1998 Part Number: 321710B-01 Please comment on the completeness, clarity, and organization of the manual.
  • Page 49 Alternating current. ANSI American National Standards Institute. American Wire Gauge. backplane An assembly, typically a printed circuit board, with connectors and signal paths that bus the connector pins. © National Instruments Corporation Value –9 – 6 –3 –2 PXI-1000 User Manual...
  • Page 50 1) grams 2) A measure of acceleration equal to 9.8 m/s GPIB General Purpose Interface Bus (IEEE 488). A measure of random vibration. The root mean square of acceleration levels in a random vibration test profile. PXI-1000 User Manual © National Instruments Corporation...
  • Page 51 Institute of Electrical and Electronics Engineers. Mainframe peak current. Inches. Pounds. Meters. MTBF Mean time between failure. MTTR Mean time to repair. NEMA National Electrical Manufacturers Association. PCI eXtensions for Instrumentation. Relative humidity. © National Instruments Corporation Glossary PXI-1000 User Manual...
  • Page 52 Installing such a device into any other slot can damage the device, the VXIbus backplane, or both. Underwriter’s Laboratories. Volts. Peak to peak voltage. Volts alternating current. Watts. PXI-1000 User Manual © National Instruments Corporation...
  • Page 53 (figure), 2-2 filler panel installation, 2-7 setting fan speed, 2-2 specifications (table), A-3 customer communication, xii, C-1 to C-2 © National Instruments Corporation DB-9 connector pinout (table), 2-5 power supply voltages (table), 2-4 DC output (table), A-2 documentation...
  • Page 54 System Controller slot (table), B-2 P2 (J2) connector peripheral slot (table), B-7 Star Trigger slot (table), B-5 System Controller slot (table), B-3 power cables (table), 1-1 to 1-2 power monitoring connector. See DB-9 connector. power problems, troubleshooting, 3-4 © National Instruments Corporation...
  • Page 55 1-7 PXI_CLK10, 1-7 PXI_CLK10_IN pin, 1-7 rack mounting, 2-2 remote power monitoring and inhibit interface, 2-5 © National Instruments Corporation safety ground, connecting, 2-3 safety specifications (table), A-3 service interval, 3-1 specifications, A-1 to A-7 backplane, A-5...

This manual is also suitable for:

Pxi-1000

Table of Contents