Hitachi 65 Instruction Manual page 253

Industrial computer
Table of Contents

Advertisement

Table 9-3 Event Log Entries Unique to the Equipment (3/3)
Event
No.
Source
ID
23
900
HFWRAS_SYS
24
2001
HFWRAS_SYS
25
2002
HFWRAS_SYS
26
2003
HFWRAS_SYS
27
2004
HFWRAS_SYS
28
2009
HFWRAS_SYS
29
2011 HFWRAS_SYS
30
2012 HFWRAS_SYS
2019 HFWRAS_SYS
31
Type
Description
Information Power shutdown factor
code is %1.
Error
The drive on the drive
bay%1 is OFFLINE
because of failure.
Information RAID status is OPTIMAL. No handling
Error
RAS could not get the
RAID status. RAID status
is UNKNOWN.
Information RAID status was revealed. No handling
Information The drive on the drive
bay%1 is OFFLINE
because of manual
operation.
Information Rebuilding was completed.
But unreadable sectors
were detected on the
source drive (Drive
bay%1). (Media error)
Error
Rebuilding failed due to
error on the destination
drive (Drive bay%1).
Information Media error is occurred on
RAID.
9-25
9. TROUBLE SHOOTING
Action
A power shutdown occurred. Contact
your system administrator or
maintenance personnel.
Read the description of abnormal
temperature in "10.4.2" and take action
accordingly.
Contact the system administrator or
maintenance personnel.
No handling
Read the description of "10.4.2" and
take action accordingly.
Read the description of "10.2.2" and
build a RAID again.
Read the description of HF-W7500
Model 65/60 RAS FEATURES
MANUAL(WIN-63-0101) "2.8.2" and
take action accordingly.

Advertisement

Table of Contents
loading

This manual is also suitable for:

Hf-w750060

Table of Contents