TECHNICAL DATA AND DIMENSIONS
Materials
Surface treatment
Max. log length
Weight Scan 5004 FRL
Weight Scan 5004 FRL
w/heat shield
Flue conn. piece internal diameter
Flue conn. piece external diameter
Approval type
* Intermittent operation in this context means normal use
of a built-in stove. In other words, you should let the fire
die down until only the embers are left before refuelling.
This built-in stove is produced in accordance with type
approval for the product, which also covers the product's
Assembly and Instruction Manual.
The Declaration of Performance (DoP) is available from
www.scan.dk
TYPE PLATE
All Scan built-in stoves are fitted with a type plate that specifies the approval standards and the distance to flammable
materials.
The type plate is placed loose in the fireplace.
Scan 5004 FRL
Freestanding room heater fired by solid fuel
Standard:
EN 13229
Minimum distance to combustible materials
Side: 400 mm - Back: 400 mm - Front: 800 mm
Minimum distance to firewall
See assembly- and instructions manual
The appliance can be operated in a shared flue.
CO emission at 13% O2:
Dust at 13% O2:
Flue gas temperature:
Nominal heat output:
Efficiency:
Fuel type:
Operation type:
Reaction to fire:
Country
Classification
Certificate/Standard
EUR
Intermittent
EN 13229
NS 3058
Norway
Germany Stufe 2
1. BlmSchV
Follow assembly- and instructions manual.
Use only recommended fuels.
Montage- und Bedienungsanleitung beachten.
Verwenden Sie nur empfohlene Brennstoffe.
1000
Scan A/S DK 5492 Vissenbjerg
Steel plate
Cast iron
Galvanised sheet
Chamotte
Senotherm
40 cm
210 kg
218 kg
175 mm
200 mm
Intermittend*
DoP 95004600
Type plate
0,09%
1173 mg/Nm³
25 mg/Nm³
221°C
7,8 kW
82,9%
Wood
Intermittent
A1
Approved by
SZU
Teknologisk Institut
08-2017
Tested in accordance with EN 13229
CO Emission at 13% O
2
CO Emission at 13% O
2
Dust @ 13% O
2
No x @ 13% O
2
Efficiency
Energy efficiency index
Energy efficiency class
Nominal output
Chimney temperature EN 13229
Temperature in flue conn. piece
Amount of smoke
Negative pressure EN 13229
Recommended negative pressure
in flue connecting piece
Required combustion air supply
Fuel
Fuel consumption
Amount of fuel required to light.
Amount of fuel, max.
0,09
%
3
1173
mg/Nm
3
25
mg/Nm
3
81
mg/Nm
83
%
111,2
A+
7,8
kW
221
°C
265
°C
6,9
g/sec
12
Pa
16-20 Pa
3
20-35 m
/h
Wood
2,2
kg/h
1,9
kg
3,25
kg
5