(6) In the same way, on the test patterns, check the blocks of COR2 through COR6
respectively. Enter the number of the block that is the least uneven print, and then
press the SET key.
Press the X key to return the machine to the initial stage of the maintenance mode.
For initialization of adjustment values
(1) Press the 5 and 8 keys in this order in the initial stage of the maintenance mode.
The "Select 58?" appears on the LCD.
(2) Press the Mono Start key.
The "1. ALL" appears on the LCD.
(3) Press the 8, 9, 5, and 4 keys in this order.
The machine initializes all paper feeding correction values.
The "CLEAR PF & EXIT" and "1. ALL" appear.
Press the X key to return the machine to the initial stage of the maintenance mode
■ Test pattern (A4)
attern
pfadj1 P
pfadj4 P
attern
attern
pfadj2 P
pfadj5 P
attern
5-33
attern
pfadj3 P
pfadj6 P
attern