Enter Setup

Check Character Verification

A check character is optional for Code 39 and can be added as the last character. It is a calculated value used to verify the
integrity of the data.
Disable: The scanner transmitsCode 39 barcodes as is.
Do Not Transmit Check Character After Verification: The scanner checks the integrity of all Code 39 barcodes to
verify that the data complies with the check character algorithm. Barcodes passing the check will be transmitted except
the last digit, whereas those failing it will not be transmitted.
Transmit Check Character After Verification: The scanner checks the integrity of all Code 39 barcodes to verify that
the data complies with the check character algorithm. Barcodes passing the check will be transmitted, whereas those
failing it will not be transmitted.
Disable
Transmit Check Character After Verification
If the Do Not Transmit Check Character After Verification option is enabled, Code 39 barcodes with a
length that is less than the configured minimum length after having the check character excluded will not
be decoded. (For example, when the Do Not Transmit Check Character After Verification option is
enabled and the minimum length is set to 4, Code 39 barcodes with a total length of 4 characters including
the check character cannot be read.)
** Exit Setup
Do Not Transmit Check Character After Verification
78