Menu 5 - Service - Nibe F470 Installer Manual

Exhaust air heat pump
Hide thumbs Also See for F470:
Table of Contents

Advertisement

Menu 5 - SERVICE

OVERVIEW
5 - SERVICE
5.1 - operating settings
5.2 - system settings
5.3 - accessory settings
5.4 - soft in/outputs
5.5 - factory setting service
5.6 - forced control
5.7 - start guide
5.8 - quick start
5.9 - floor drying function
5.10 - change log
5.12 - country
* Accessory needed.
Go to the main menu and hold the Back button in for 7
seconds to access the Service menu.
Sub-menus
Menu
SERVICE
has orange text and is intended for the
advanced user. This menu has several sub-menus.
Status information for the relevant menu can be found
on the display to the right of the menus.
operating settings
Operating settings for the heat
pump.
system settings
System settings for the heat pump,
activating accessories etc.
accessory settings
Operational settings for different
accessories.
soft in/outputs
Setting software controlled in and out-
puts on the input circuit board (AA3).
factory setting service
Total reset of all settings (includ-
ing settings available to the user ) to default values.
forced control
Forced control of the different compon-
ents in the heat pump.
start guide
Manual start of the start guide which is run
the first time the heat pump is started.
quick start
Quick starting the compressor.
NOTE
Incorrect settings in the service menus can
damage the heat pump.
NIBE F470
5.1.1 - hot water settings
5.1.2 - max flow line temperature
5.1.4 - alarm actions
5.1.5 - fan sp. exhaust air
5.1.6 – fan sp. supply air
5.1.12 - internal electrical addition
5.1.99 - other settings
5.2.4 - accessories
5.3.3 - extra climate system *
5.3.21 - flow sensor / energy meter*
MENU 5.1 - OPERATING SETTINGS
Operating settings can be made for the heat pump in
the sub menus.
MENU 5.1.1 - HOT WATER SETTINGS
economy
Setting range start temp. economy: 15 - 52 °C
Factory setting start temp. economy: 45 °C
Setting range stop temp. economy: 15 - 55 °C
Factory setting stop temp. economy: 51 °C
normal
Setting range start temp. normal: 15 - 52 °C
Factory setting start temp. normal: 49 °C
Setting range stop temp. normal: 15 - 55 °C
Factory setting stop temp. normal: 55 °C
luxury
Setting range start temp. lux: 15 - 62 °C
Factory setting start temp. lux: 52 °C
Setting range stop temp. lux: 15 - 65 °C
Factory setting stop temp. lux: 58 °C
stop temp. per. increase
Setting range: 55 – 70 °C
Factory setting: 60 °C
Chapter 8 | Control - Menus