Menu 5 - SERVICE

OVERVIEW
5 - SERVICE
5.1 - operating settings
5.2 - system settings
5.3 - accessory settings
5.4 - soft in/outputs
5.5 - factory setting service
5.6 - forced control
5.7 - start guide
5.8 - quick start
5.9 - floor drying function
5.10 - change log
5.12 - country
* Accessory needed.
Go to the main menu and hold the Back button in for 7
seconds to access the Service menu.
Sub-menus
Menu
SERVICE
has orange text and is intended for the ad-
vanced user. This menu has several sub-menus. Status in-
formation for the relevant menu can be found on the display
to the right of the menus.
operating settings
Operating settings for the heat pump.
system settings
System settings for the heat pump, activ-
ating accessories etc.
accessory settings
Operational settings for different ac-
cessories.
soft in/outputs
Setting software-controlled inputs and
outputs on input board (AA3).
factory setting service
Total reset of all settings (including
settings available to the user ) to default values.
forced control
Forced control of the different components
in the heat pump.
start guide
Manual start of the start guide which is run the
first time the heat pump is started.
quick start
Quick starting the compressor.
NOTE
Incorrect settings in the service menus can dam-
age the heat pump.
MENU 5.1 - OPERATING SETTINGS
Operating settings can be made for the heat pump in the
sub menus.
44
Chapter 8 | Control - Menus
5.1.1 - hot water settings
5.1.2 - max flow line temperature
5.1.4 - alarm actions
5.1.5 - fan sp. exhaust air
5.1.6 – fan sp. supply air
5.1.12 - internal electrical addition
5.1.99 - other settings
5.2.4 - accessories
5.3.3 - extra climate system *
5.3.21 - flow sensor / energy meter*
MENU 5.1.1 - HOT WATER SETTINGS
NOTE
The factory set tap water temperatures specified
in the manual can vary due to the directives in
force in different countries. From this menu, you
can check the relevant settings for the system.
economy
Setting range start temp. economy: 15 - 52 °C
Factory setting start temp. economy: 45 °C
Setting range stop temp. economy: 15 - 55 °C
Factory setting stop temp. economy: 51 °C
normal
Setting range start temp. normal: 15 - 52 °C
Factory setting start temp. normal: 49 °C
Setting range stop temp. normal: 15 - 55 °C
Factory setting stop temp. normal: 55°C
luxury
Setting range start temp. lux: 15 - 62 °C
Factory setting start temp. lux: 52°C
Setting range stop temp. lux: 15 - 65 °C
Factory setting stop temp. lux: 58 °C
stop temp. per. increase
Setting range: 55 – 70 °C
Factory setting: 60 °C