Possible selections for AUX output
Indication
• alarm
• holiday
• away mode for "smart home" (complement to the
functions in menu 4.1.7)
Control
• circulation pump for hot water circulation
• external heating medium pump
• external damper for frost protection.
Blocking
• supply air heating (accessory BSA 10 is required)
NOTE
The relevant distribution box must be marked
with a warning about external voltage.
An external circulation pump is connected to the AUX
output, as illustrated below.
AA3-X7
Connecting
accessories
Instructions for connecting accessories are provided in
the manual accompanying the accessory. See
for the list of the accessories that can be used with
F470.
32
Chapter 5 | Electrical connections
1 2 3
C NO NC
AA3-X7
F1X45
F470
External
Externt
L
N
PE
L
N
PE
Circulation pump
page 61