calibrated your speedometer so you don't accumulate extra miles. You can preset the
miles as many times as needed to get it correct until you have driven 100 miles.
In the MAIN-SYSTEM-DISPLAY
• Rotate the Control knob to highlight SET ODOM, tap to select
• The current miles will be displayed with the left most digit flashing
• Rotate the knob to the desired digit (0-9), tap knob to select that digit or rotate the knob
until BACK is highlighted and tap to return one digit to the left.
• The digit will be displayed and the next digit to the right will start to flash
• Again rotate the knob to the desired digit, tap to select
• Continue this process until the right most digit has been set.
Note: Tenths of a mile cannot be entered.
• The system will return to the DISPLAY menu with SET ODOM highlighted.
EXTRA LABEL
This is a list of hardware triggers that can be can be wired to the GRAFIX Control Box. As
discussed below these include defined default factory triggers, as well as user defined triggers
that include custom labels that will be displayed on the GRAFIX Instrument Cluster when
activated.
The two extra, universal inputs are indicated on the Control Box as EX- and EX+. EX- is
activated by grounding the input and the EX+ is activated by an active high input. When the input
is activated, a message will be shown on the GRAFIX Message Area display. The user can
customize the text label for these inputs with up to 8 characters, and can select whether the
message is shown for only a few seconds or whether it should remain until the input is released.
The user can also select whether the message is for information purposes only or as a system
warning. As a warning the message will be highlighted in red in the Message Area. For added
flexibility and if more inputs are needed, the WAIT input and 4x4 input can also be configured to
be 'extra', universal inputs instead of being used for their default operation.
Also, any one of these 4 inputs (EX+, EX-, WAIT/EX, and 4x4/EX) can be configured as the
trigger to light up the GRAFIX gauge system when a door is opened. When used as DOOR
OPEN trigger, the Instrument Cluster will light up with the splash screens as configured, and the
odometer reading will remain on for approximately 1 minute or until the key (ignition) is turned on.
The EX+ and the WAIT/EX inputs can also be configured as the trigger for the camera input, and
when activated will display the GRAFIX camera port's video on the Instrument Cluster.
3232
Note: If an input (EX+, EX-, WAIT, or 4x4) is configured as a trigger for either the 'DOOR
OPEN' or the 'CAMERA', they will grayed out in the MAIN-SYSTEM-DISPLAY-EXTRA
LABEL sub-menu list, and cannot be configured/used as other GRAFIX trigger inputs.
In the MAIN-SYSTEM-DISPLAY
• Rotate the Control knob to highlight EXTRA LABEL, tap to select
• Menu list: EX+, EX-, WAIT, 4X4, DOOR OPEN, and BACK will be displayed
• Rotate the knob if needed to highlight EX+, tap to select
• Menu options shown are "LABEL", "DISPLAY", "TYPE", and "BACK"
• Rotate the knob to any of the menu items, tap to select
• Following the instructions below for the menu selection chosen
LABEL (Message label setup)
The default GRAFIX labels are EX+, EX-, WAIT, and 4X4. These can be customized with up
to 8 characters – including: letters, numbers, "/", ".", "-", ",", "+", "*", "!", and " "(blank space).