asshown in the diagramincluded in thismanual.
2.
The HSPA3G Cellular path isimmune to conducted and radiated RF fields
with levelsup to 10V/mastested per EN50130- 4 Standard.
3.
The TL2803G(R)E-EU/3G2080(R)E-EU/TL280(R)Emodule conformswith
radiated emissionslevelsfor ClassBequipment asper standardsEN61000-
6-3/EN55022/CISPR22.
4.
The TL2803G(R)E-EU/3G2080(R)E-EU/TL280(R)Emodule usesAES128
encryption and heartbeat supervision for HSPA3G Cellular communication
pathsand it meetssecuritylevelsS2 asper EN50136-2:2013. It also uses
authentication for each message exchanged with the compatible receiver
equipment at ARC and it meetslevelI2 for information security.
5.
The 3G2080(R)E-EU module hasonlyone communication path:
HSPA3G Cellular communication path using 900/1800/2100MHzPublicCel-
lular Network. The HSPA3G Cellular communication path that can be used in
a standalone mode in conjunction with a DSC alarmsystem(compatible DSC
alarmcontrolpanelmodels: HS2128/064/032/016). The supported ATScon-
figuration is: customcategoryC.
6.
The TL280(R)Emodule hasonlyone communication path: Ethernet com-
munication path using Internet. The communication path that can be used in
a standalone mode in conjunction with a DSC alarmsystem(compatible DSC
alarmcontrolpanelmodels: HS2128/064/032/016). The supported ATScon-
figuration is: customcategoryC.
7.
The TL2803G(R)E-EU module hastwo communication paths: HSPA3G Cel-
lular communication path using 900/1800/2100MHzPublicCellular Network
and Ethernet communication path using Internet. The communication paths
can be used in a standalone mode in conjunction with a DSC alarmsystem
(compatible DSC alarmcontrolpanelmodels: HS2128/064/032/016). The
supported ATSconfiguration is: customcategoryC.
8.
TL2803G(R)E-EU/3G2080(R)E-EU/TL280(R)Ehasbeen tested for com-
pliance in conjunction with the following applicable standards: EN50136-
1:2012, EN50136- 2:2013, EN50131-10:2014, ATSconfiguration: C.
For EN50131- 1:2006/A1:2009 compliant installations, the following pro-
gramming optionsshallbe set asdescribed.
Supervision Heartbeat:
•shallbe set to 180 seconds
NOTE: The compatible receiver at ARC location shall have supervision window
programmed for 180 seconds. TL2803G(R) E-EU/3G2080(R) E-EU/TL280(R) E
has been certified by TELEFICATION in accordance with EN50131-
1:2006/A1:2009, EN50131- 10:2014 requirements for Grade 2, Class II and
EN50136-2:2013 Configuration: C
ATS Custom Category C
EN50136-1:2012 AnnexD Table D.1 D3
EN50136-1:2012 AnnexD Table D.2 M3
EN50136-1:2012 AnnexD Table D.3 T4
EN50136-1:2012 AnnexD Table D.4 A4 (Depending on cellular carrier used)
EN50136-1:2012 AnnexD Table D.5
EN50136-1:2012 AnnexD Table D.6 I2 (use AES-128 encryption)
EN50136-1:2012 Table 1
EN50136-1:2012 Table 4
EN50136-1:2012 Table 5
EN50136-1:2012 Table 6
EN50136-2:2013 Table 1
EN50136-2:2013 Table 2
EN50136-2:2013 Table 3
Level
S2
(use
AES- 128
authentication/sequential information
in each message transmitted to the SG
receiver)
Use single communication path for
models 3G2080 (R) E- EU (cellular
network), TL280 (R) E (Ethernet port)
and two communication paths for
model
TL2803G
(R) E-
(cell/Ethernet).
ATSfailure reported to ARC
ATS failure reported to AS (DSC
compatible
control
HS2128/HS2064/HS2032/HS2016)
There is no recording of availability
failure
No logging function provided
No memory provided for logging
function
ATSfailure reported to ARC
UL/ULC Installation Requirements
NOTE: For equipment used at the protected premisesand intended to facilitate
IP communications (hubs, routers, NIDs, Digital Subscriber Line (DSL), cable
modems), 24 hour backup power isrequired. Where such cannot be facilitated, a
secondary(back-up) communication channelisrequired.
Domain Name Service (DNS) programming is not permitted in
UL1610 listed systems.
Technical Specifications
The input voltage to the Communicator can be drawn fromthe UnderwritersLab-
oratories/UnderwritersLaboratoriesCanada (UL/ULC) listed controlpanel.
Notes for using Private, Corporate, and High Speed Data Net-
works:
Networkaccess and domain access policiesshall be set to restrict unauthorized
networkaccess, and spoofing or Denialof Service (DoS) attacks. Select an Inter-
net Service Provider (ISP) that has redundant servers/systems, back- up power,
routerswith firewallsenabled, and methods to identify and protect against DoS
attacks(e.g., via spoofing).
Notes for using Public Switched and Cellular Data Networks:
and
Communication channels shall be facilitated such that the communicator will
restrict unauthorized access, which could otherwise compromise security. The
communicator shallbe located in a secured area.
•For ULC Residential Fire and Burglary applications the TL2803G (R)
E/3G2080(R)E/TL280 (R)E can be used as primary communication channel via
either cellular or Ethernet or asa back-up in conjunction with the DigitalAlarmCom-
municator Transmitter (DACT). Test transmission every24 hoursshallbe enabled
on each channel.
•For ULC Commercial Fire and Burglary applications the TL2803G (R)
EU
E/3G2080(R)E/TL280(R)Ecan be used asa passive communication module with
the following securitylevels:
P1 (each channelcellular or Ethernet isindependent)
l
P2 (cellular and Ethernet in back-up configuration, panelsection [851][005]
l
toggle option [5] OFF).
panel
P3 (cellular and Ethernet in redundant configuration, panelsection [851]
l
[005] toggle option [5] ON).
The communicator can also be used asan active communication systemwith the
securitylevelsA1-A4 (each channelcellular or Ethernet independent or together
in a back-up/redundant configuration). For active line securitysystemsAES128 bit
encryption shall be enabled (at the monitoring station receiver) and the super-
vision heartbeat rate shall be set as 90 seconds (panel section [851] [004] =
005A/90). The supervision window at the Signal Receiver Center (SRC) 's
receiver shallbe programmed asmaximumof 180 (00B4/180) seconds.
• For UL Residential Fire and Burglary applications the TL2803G (R)
E/3G2080R/TL280(R)E can be used as the primary communication channel via
either cellular or Ethernet, or asa back-up in conjunction with the DACT (30 day
test transmission isrequired on each channel).
• For UL
Commercial
E/3G2080R/TL280(R)E can be used as dualsignalling line communication sys-
tem(cellular and Ethernet channels used in redundant configuration), standard
line securityand asencrypted line security.
•The supervision heartbeat shall be enabled (panelsection [851] [005] toggle
option [1] (Ethernet) and/or toggle option [2] (cellular) shallbe ON), toggle option
[3] (supervision type) shall be ON and the supervision heartbeat rate shall be
selected as135 (0087/135) seconds. Option [004] = 0087. The supervision win-
dow at the supervising station shall be maximum200 (00C8/200) seconds. For