Led Functions; Led Details; Led L1 (Red) - DSC neo 3G8080I Installation Manual

Hspa/cdma controller
Hide thumbs Also See for neo 3G8080I:
Table of Contents

Advertisement

Status LEDs

LED Functions

LED
Error LED. Flashes 1 to 8 times in an 8-second interval to indicate specific error. See section "LED L1 (red)" for
L1
errors and common fixes.
Panel Communication and Z-Wave status messages. Flashes every time the module communicates with the
L2
panel and flashes in patterns to indicate Z-Wave status.
HSPA /CDMA Communication. Flashes every time the HSPA/CDMA signal level is checked and when
L3
packets are exchanged with Alarm.com.
HSPA/CDMA Signal Level. Flashes 0 to 5 times to indicate signal strength, or toggles on/off slowly when
L4
communicating with Alarm.com servers.
L5
Z-Wave Error LED. See section "LED L5 (yellow)" for error descriptions.

LED Details

LED L1 (Red)

L1 flashes when there is an error. The number of flashes indicates the error number. If there are two or more
errors at the same time, the errors will flash one after the other. The LED will stay off for at least four
seconds between errors.
Number
of
Flashes
Module cannot communicate with the panel. Ensure section [382] option [5] is ON. Verify panel
software is version 1.1 or higher. Check the connectors (between the panel and communicator) and
1
powercycle the panel. If the error persists, there may be an issue with the module or panel.
L1 L2 L3 L4 L5
Function
Error and Solution
- 17 -