Check After Starting - Hitachi ZW140-6 Operator's Manual

Wheel loader
Table of Contents

Advertisement

Check After Starting

IMPORTANT: If any abnormality is found in the
monitor functions, immediately stop the engine and
investigate the cause of the trouble.
Check the monitor operation:
1. Check that discharge warning indicator (1) is OFF.
In case the discharge warning indicator stays ON,
immediately stop the engine. Inspect the alternator and
battery system for any abnormality.
2. Check that low engine oil pressure indicator (2) is OFF.
In case the low engine oil pressure indicator stays ON,
immediately stop the engine. Inspect the engine oil
pressure system and the oil level.
3. Check that engine coolant temperature gauge (3) is
within range (4).
f
NOTE: To check indicator bulbs and the buzzer function,
when the key switch is turned ON, monitor indicators come
ON and continue to stay ON for approx. 2 seconds.
Check engine noise and exhaust gas color:
Check that the engine noise and exhaust gas color is
normal.
f
NOTE: Check the exhaust gas color as follows. (After warm-
up operation, run the engine with no loads.)
Clear or light blue : Normal (Perfect combustion)
Black
: Abnormal (Imperfect combustion,
abnormal aftertreatment device,
abnormal fuel system)
White
: Abnormal (Oil is leaking into the
combustion chamber, abnormal
aftertreatment device, abnormal
fuel system)
f
NOTE: White smoke may occur for several minutes after the
engine starts, this is not a malfunction.
OPERATING ENGINE
2
3-8
3
4
1
MPTC-01-019

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Zw150-6Zw150pl-6

Table of Contents