Change Coolant - Hitachi ZW140-6 Operator's Manual

Wheel loader
Table of Contents

Advertisement

Change Coolant

--- every 2000 hours or two years
d
CAUTION: Do not remove expansion tank cap (1)
until the coolant temperature in the radiator is cool.
Hot steam may spout out, possibly causing severe
burns. After the coolant temperature cools, slowly
loosen cap (1) to release the inside air pressure before
removing cap (2).
IMPORTANT: Use Hitachi genuine coolant. Change the
coolant every two years or 2000 hours whichever
comes first.
1. Park the machine following the same procedures as
described on page 7-7 for preparation of inspection/
maintenance work.
2. Install articulation lock bar to the front and rear of the
frame by following the procedures described on page
7-9.
3. Remove expansion tank cap (1). Turn up rubber cover
(2). Open radiator drain cock (3) and engine water jacket
drain plug to completely drain the coolant. Remove
impurities such as scale at the same time.
4. Close radiator drain cock (3). Supply low impurity soft
water or tap water together with the specified LLC up
to the radiator filler port. When adding coolant, do so
slowly to avoid mixing in the system.
Start the engine and sufficiently bleed air from the
cooling system.
f
NOTE: When refilling a long-life coolant, pour it at flow rate
10 L/min or below. If flow rate is larger than the above, air
does not bleed, being unable to fill the specified amount.
5. After adding coolant, operate the engine for several
minutes. Check the coolant level again and add coolant
if necessary.
MAINTENANCE
7-77
1
MPTC-07-008
MPTC-07-016
2
MPTC-07-017
3

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Zw150-6Zw150pl-6