ENOM00085-A
Flushing by test tank
ENOW00081-1
WARNING
Do not start engine without removing pro-
peller, turning propeller out in the open may
lead to personal injury.
ENOW00082-0
WARNING
Never start or operate the engine indoors or
in any space which is not well ventilated.
Exhaust gas contains carbon monoxide, a
colorless and odorless gas which can be fatal
if inhaled for any length of time.
ENOW00036-1A
CAUTION
When starting the outboard motor in the
test tank, make sure that:
1. Water level is at least 10 cm (4 in.) above
the anti-ventilation plate to avoid over-
heating of the engine.
2. Run at idling only
3. Remove the propeller
(See page 55)
3
2
1. Test tank
2. Water
3. Over 10 cm (4 in.)
ENOM01903-0
Gear case flushing device
ENOW00082-0
Never start or operate the engine indoors or
in any space which is not well ventilated.
Exhaust gas contains carbon monoxide, a
colorless and odorless gas which can be fatal
if inhaled for any length of time.
ENOW00986-0
Never leave the outboard motor unattended
while running on the flushing devise. When
the flushing devise slip off from the gear
case, the engine will overheat and may cause
serious damage.
1. Fully tilt down the outboard motor.
2. With the propeller removed, seal the
sub-water inlet with a tape to prevent
air from being sucked into the water
pump.
1
1. Sub-water inlet
2. Tape
3. Install the gear case flushing device on
gear case so that the rubber cups
ENOF00863-0
cover the cooling water inlets tightly.
INSPECTION AND MAINTENANCE
WARNING
CAUTION
1
2
49
10
ENOF02559-0

Advertisement