Operation

Operation

Pressure Relief Procedure

Follow the Pressure Relief Procedure whenever
you see this symbol.
This equipment stays pressurized until pressure is
manually relieved. To help prevent serious injury
from pressurized fluid, such as splashing fluid and
moving parts, follow the Pressure Relief Procedure
when you stop operating and before cleaning,
checking, or servicing the equipment.
1. Turn the fluid output control knob (K) to off (0) and
disconnect power to the system.
2. Close the fluid shutoff valve (H).
3. Open the fluid drain valve (G) to relieve fluid
pressure. Prepare a container to catch the
drainage.
4. Leave the fluid drain valve (G) open until the system
is ready to be pressurized.

Before Each Use

Tighten Fasteners
Check and tighten all fasteners before operating the
equipment.
NOTICE
To avoid pump damage, do not over-tighten the
fasteners on the equipment.
Tighten Connections
Check and tighten all fluid connections before operating
the equipment. Replace worn or damaged parts as
needed.
NOTICE
Firmly tighten all connections to avoid leaks and
damage to equipment parts.
22
Triplex Sales
1-847-839-8442
www.triplexsales.com
Flush the Equipment
Flush the equipment before each use. Determine
whether to disassemble and clean individual parts or
simply flush the equipment with a compatible sanitizing
solution.
To simply flush the equipment with a compatible
sanitizing solution, follow Start the Equipment, page
22, and Flush the Equipment, page 27.
To disassemble and clean individual parts, see the
applicable repair procedure. See Repair, starting on
page 31.

Start the Equipment

To prevent serious injury from splashing fluid,
ensure the control knob (K) is set to off (0) before
connecting the equipment to a power source.
Prepare the Equipment for Startup
1. Turn the control knob (K) to off (0).
2. Confirm that the equipment is properly grounded.
See Grounding, page 15.
3. Check and tighten all fasteners and connections
before operating the equipment. Replace worn or
damaged parts as needed.
4. Insert the suction end of the fluid supply line (F) into
the fluid to be dispensed.
5. Insert the outlet end of the fluid outlet line (J) into
the end container.
6. Close the fluid drain valve (G).
7. Ensure all fluid shutoff valves (H) are open.
8. If the fluid outlet line (J) has a dispensing device,
hold the dispensing valve open into the end
container.