Graco Husky 2200 Operation

Graco Husky 2200 Operation

Air-operated diaphragm pump
Hide thumbs Also See for Husky 2200:

Advertisement

Quick Links

Operation
Husky™ 2200
2200 Air
Husky™
Husky™
2200
Diaphragm Pump
Diaphragm
Diaphragm
Polypropylene and
Polypropylene
Polypropylene
and PVDF
and
PVDF
PVDF pumps
professional use
professional
professional
use only.
use
only.
only.
Not for
for use
use in in in European
European explosive
Not
Not
for
use
European
Important
Important
Important Safety
Safety Instructions
Safety
Read all warnings and instructions in this manual and in your
Repair/Parts manual. Save
Maximum Working Pressure: 125 psi
(0.86 MPa, 8.6 bar)
Tel: 866-777-6060
Fax: 866-777-6383
Air - - - Operated
Operated
Air
Operated
Pump
Pump
pumps for
pumps
for fluid
for
fluid
fluid transfer
transfer applications,
transfer
explosive atmosphere
atmosphere locations.
explosive
atmosphere
Instructions
Instructions
Save these
these instructions.
instructions.
Save
these
instructions.
PROVEN QUALITY. LEADING TECHNOLOGY.
Springer Pumps, LLC
applications, including
applications,
including high
including
locations.
locations.
3A2578E
high viscosity
high
viscosity materials.
viscosity
materials. For
materials.
Website: www.springerpumps.com
Int'l: +001 267 404 2910
EN
For
For

Advertisement

Table of Contents
loading

Summary of Contents for Graco Husky 2200

  • Page 1 Operation Husky™ 2200 2200 Air Air - - - Operated Operated Husky™ Husky™ 2200 Operated Diaphragm Diaphragm Pump Diaphragm Pump Pump 3A2578E Polypropylene Polypropylene and Polypropylene and PVDF PVDF PVDF pumps pumps pumps for for fluid fluid fluid transfer transfer transfer applications, applications, applications, including...
  • Page 2: Table Of Contents

    Dimensions ............18 Fluid Supply Line ......... 11 Performance Charts..........20 Fluid Outlet Line........... 12 Technical Data ........... 22 Flange Connections ........13 Graco Standard Husky Pump Warranty....24 Operation ............14 Pressure Relief Procedure......14 3A2578E Springer Pumps, LLC Tel: 866-777-6060 Website: www.springerpumps.com...
  • Page 3: Warnings

    Warnings Warnings Warnings Warnings The following warnings are for the setup, use, grounding, maintenance, and repair of this equipment. The exclamation point symbol alerts you to a general warning and the hazard symbols refer to procedure-specific risks. When these symbols appear in the body of this manual or on warning labels, refer back to these Warnings.
  • Page 4 Warnings WARNING WARNING WARNING EQUIPMENT EQUIPMENT EQUIPMENT MISUSE MISUSE HAZARD MISUSE HAZARD HAZARD Misuse can cause death or serious injury. • Do not operate the unit when fatigued or under the influence of drugs or alcohol. • Do not exceed the maximum working pressure or temperature rating of the lowest rated Technical Data Data in all equipment manuals.
  • Page 5 Warnings WARNING WARNING WARNING BURN BURN BURN HAZARD HAZARD HAZARD Equipment surfaces and fluid that’s heated can become very hot during operation. To avoid severe burns: • Do not touch hot fluid or equipment. PERSONAL PERSONAL PERSONAL PROTECTIVE PROTECTIVE PROTECTIVE EQUIPMENT EQUIPMENT EQUIPMENT Wear appropriate protective equipment when in the work area to help prevent serious injury,...
  • Page 6: Ordering Information

    To Order Order Order Replacement Replacement Replacement Parts Parts Parts ordering information, as needed. 3. Please call Graco Customer Service to order. Please Please call Please call your call your your distributor. distributor.
  • Page 7: Configuration Number Matrix

    Configuration Number Matrix Configuration Configuration Configuration Number Number Matrix Number Matrix Matrix Check the identification plate (ID) for the Configuration Number of your pump. Use the following matrix to define the components of your pump. 2200P 2200P 2200P- - - PP01AP1PPPTFKPT PP01AP1PPPTFKPT PP01AP1PPPTFKPT Sample...
  • Page 8: Installation

    25 % of the outlet working pressure. selecting and installing system components. Contact 3. Reduce liquid velocity: Slow the cyclic rate of your Graco distributor for assistance in planning a the pump. system to suit your needs. Always use Genuine Graco Parts and accessories.
  • Page 9 Installation Accessories/Components Accessories/Components Not Accessories/Components Not Supplied Supplied Supplied System System Components System Components Components Air supply line Air inlet port (not visible) Bleed-type master air valve (may be Air exhaust port and muffler required for your pump) Air filter/regulator assembly Fluid inlet port Fluid outlet port Master air valve (to isolate the...
  • Page 10: Ground The System

    Installation Ground The The System System Air Lines Lines Lines Ground Ground System 1. Install an air filter/regulator assembly (C). The regulator controls the fluid pressure. The fluid stall pressure will be the same as the setting of the air regulator. The filter removes harmful dirt and moisture from the compressed air supply.
  • Page 11: Air Exhaust Ventilation

    Installation Air Exhaust Exhaust Exhaust Ventilation Ventilation Ventilation To provide provide a a a remote remote exhaust: exhaust: provide remote exhaust: 1. Remove the muffler (U) from the pump air exhaust port (K). 2. Install a grounded air exhaust hose (S) and If pumping toxic fluids, you must vent the exhaust connect the muffler to the other end of the hose.
  • Page 12: Fluid Outlet Line

    Installation Fluid Fluid Fluid Outlet Outlet Line Outlet Line Line 2. If the inlet fluid pressure to the pump is more than 25% of the outlet working pressure, the ball check valves will not close fast enough, 1. Use grounded, flexible fluid hoses. See resulting in inefficient pump operation.
  • Page 13: Flange Connections

    Installation Flange Connections Connections Flange Flange Connections The fluid inlet and outlet ports are 2 in. (50 mm) raised face, ANSI/DIN PN 10 flanges. Connect 2 in. (50 mm) plastic pipe flange to the pump as follows. You will need: •...
  • Page 14: Operation

    Operation Operation Operation Operation Pressure Pressure Relief Pressure Relief Procedure Relief Procedure Procedure 3. Place the suction tube (if used) in fluid to be pumped. Follow the Pressure Relief Procedure NOTE: NOTE: NOTE: If fluid inlet pressure to the pump is more whenever you see this symbol.
  • Page 15: Maintenance

    Maintenance Maintenance Maintenance Maintenance Maintenance Maintenance Maintenance Schedule Schedule Schedule Flushing Flushing Flushing and and Storage Storage Storage Establish a preventive maintenance schedule based on the pump’s service history. Scheduled maintenance is especially important to prevent spills or leakage due to diaphragm failure. Lubrication Lubrication Lubrication...
  • Page 16: Torque Instructions

    Torque Instructions Torque Torque Instructions Torque Instructions Instructions If fluid cover or manifold fasteners have been Inlet and and Outlet Outlet Manifold Manifold Screws Screws Inlet Inlet Outlet Manifold Screws loosened, it is important to torque them using the following procedure to improve sealing. NOTE: NOTE: Fluid cover and manifold fasteners have a NOTE:...
  • Page 17: Notes

    Notes Notes Notes Notes 3A2578E Springer Pumps, LLC Tel: 866-777-6060 Website: www.springerpumps.com Fax: 866-777-6383 Int'l: +001 267 404 2910...
  • Page 18: Dimensions

    Dimensions Dimensions Dimensions Dimensions End Flange Flange Flange Models, Models, Polypropylene Models, Polypropylene Polypropylene and PVDF PVDF PVDF Polypropylene Polypropylene Polypropylene PVDF PVDF PVDF Polypropylene Polypropylene Polypropylene PVDF PVDF PVDF A A A G G G 25.1 in. 63.8 cm 25.2 in.
  • Page 19 Dimensions Center Flange Flange Models, Models, Polypropylene Polypropylene Center Center Flange Models, Polypropylene Only Only Only Polypropylene Polypropylene Polypropylene Polypropylene Polypropylene Polypropylene A A A 24.1 in. 61.2 cm G G G 18.5 in. 47.0 cm B B B H H H 27.2 in.
  • Page 20: Performance Charts

    Performance Charts Performance Charts Charts Performance Performance Charts Bolt - - - through through Diaphragms Diaphragms Bolt Bolt through Diaphragms Fluid Pressure Pressure Fluid Fluid Pressure Approximate Cycles Cycles per per Minute Minute Approximate Approximate Cycles Minute (0.86, 8.6) (0.70, 7.0) (0.52, 5.2) Operating Operating...
  • Page 21 Performance Charts Overmolded Overmolded Overmolded Diaphragms Diaphragms Diaphragms Fluid Fluid Pressure Fluid Pressure Pressure Approximate Approximate Approximate Cycles Cycles per Cycles per Minute Minute Minute (0.86, 8.6) (0.70, 7.0) (0.52, 5.2) Operating Air Air Pressure Pressure Operating Operating Pressure (MPa, (MPa, (MPa, bar) bar)
  • Page 22: Technical Data

    Technical Data Technical Technical Data Technical Data Data Husky Husky Husky 2200 2200 2200 Diaphragm Diaphragm Pump Diaphragm Pump Pump Metric Metric Metric Maximum fluid working pressure 125 psi 0.86 MPa, 8.6 bar Air pressure operating range 20 to 125 psi 0.14 to 0.86 MPa, 1.4 to 8.6 bar...
  • Page 23 Technical Data Maximum Maximum pump Maximum pump pump speed speed speed Standard diaphragms 125 cycles per minute 155 cycles per minute Overmolded diaphragms Weight Weight Weight Polypropylene 80 lb 36.3 kg PVDF 106 lb 48.1 kg Wetted Wetted Parts Wetted Parts Parts Wetted parts include material(s) chosen for seat, ball, and diaphragm options, plus...
  • Page 24: Graco Standard Husky Pump Warranty

    Graco to be defective. This warranty applies only when the equipment is installed, operated and maintained in accordance with Graco’s written recommendations. This warranty does not cover, and Graco shall not be liable for general wear and tear, or any malfunction, damage or wear caused by faulty installation, misapplication, abrasion, corrosion, inadequate or improper maintenance, negligence, accident, tampering, or substitution of non-Graco component parts.

Table of Contents