Cleaning, Maintenance; Filter Change - Maico ER-UP Mounting And Operating Instructions

Recess-mounted exhaust air system according to din 18017-3
Table of Contents

Advertisement

16. Installation of fan insert and cover

16. Cleaning, maintenance

The unit is practically maintenance-free.
The air filter simply needs replacing every
3 to 6 months, depending on the amount of
dirt.
DANGER
Danger to life from electric shock.
 Prior to accessing the connection
terminals, switch off all supply circuits.
Switch off mains fuse, secure against
being accidentally switched back on and
position a visible warning sign.
NOTICE
The unit will be damaged if incorrect
cleaning agent is used.
 Do not use aggressive cleaning agents.
1. Only use a dry cloth to clean the cover [15]
of the fan.
2. If the cover is very dirty, remove it and
clean with water.
38

16.1 Filter change

19
15 Cover
17 Filter mat, filter class G2
Filter change interval every 3 to
6 months, depending on the
amount of dirt.
1. Fold up cover [15].
2. Take out filter mat [17] and replace it.
3. Place filter mat on intake grille cover [15]
and lock cover. The lock must engage
audibly.
Filter mats ZF 60/100:
Pack of 5, filter class G2
in accordance with EN 779,
Art. no. 0093.0680