Flush-mounted exhaust air elements for centro centralised ventilation system according to din 18017-3

Advertisement

Quick Links

Installation and operating instructions
Flush-mounted exhaust air elements for Centro centralised
ventilation system according to DIN 18017-3
www.maico-ventilatoren.com
Centro-M
Centro-E
Centro-H

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the Centro-M and is the answer not in the manual?

Questions and answers

Summary of Contents for Maico Centro-M

  • Page 1 Installation and operating instructions Flush-mounted exhaust air elements for Centro centralised ventilation system according to DIN 18017-3 Centro-M Centro-E Centro-H www.maico-ventilatoren.com...
  • Page 2: Table Of Contents

    Table of contents Table of contents Scope of delivery ........Specialist installer qualifications ..Intended use.......... Safety instructions and warnings ..System and product information ..5.1 Centro centralised ventilation sys- tem..........5.2 Certificates of approval....5.3 Permitted exhaust air systems ..5.4 Installation conditions .....
  • Page 3: Scope Of Delivery

    3 Intended use • in central ventilation systems with a common Centro-M/Centro-E/Centro-H exhaust air ele- main duct; ments are intended for use in centralised ventila- • with an air supply via shaft or duct;...
  • Page 4: Exhaust Air Elements

    • with the outside air openings stated in the plan- • Trouble-free filter change without tools. ning documents; • Centro-M with protection class II. Installation • Centro-E/Centro-H: pressure controller for the also permissible with water jets (DIN VDE centralised fan required.
  • Page 5: Technical Data Table

    6.4 Storage Only store unit horizontally in a suitable, dry room. Ambient temperature – 10 °C to + 60 °C. Maico accepts no liability for corrosion damage caused by improper storage, e.g. storage in a damp environment. 7 Mounting preparations 8.3 Installation of spiral housing and...
  • Page 6 Centro-M with fixed air volume setting. The housing floor seal must lie flat and without Centro-E and Centro-H with fixed air volume any creases in the housing.
  • Page 7: Installing The Cover

    If installing on a wall, ensure that the hindered. Maico name is in the bottom right. 4. Switch off unit. • If the housing edge is flush with the plaster, use...
  • Page 8: Cleaning, Maintenance

    11 Cleaning, maintenance switch. Demand-based ventilation after start delay 12 Fault rectification of approx. 1 minute. Overrun time after switching Fault finding and repairs only permissible off, approx. 3 minutes. when carried out by qualified electricians. Control of the volumetric air flows within the vent- ilation system with Centro pressure controller.
  • Page 9: Spare Parts

    → Re-calculate pressure losses. In case of questions, please contact: H model does not No rapid increase in hu- Maico Elektroapparate-Fabrik GmbH switch from base load midity (7% in 2 minutes) Steinbeisstraße 20 to full load operation took place.
  • Page 10: Removing The Housing

    14 Removing the housing 14 Removing the housing 16 Environmentally responsible disposal The ventilation unit and the packaging contain parts that can be recycled, and should not end up in the domestic waste. Dispose of the packaging material in an environ- mentally-friendly way, in compliance with the reg- ulations valid in the country where you are.
  • Page 11 Notes...
  • Page 12 Maico Elektroapparate-Fabrik GmbH Steinbeisstr. 20 78056 Villingen-Schwenningen Deutschland Service +49 7720 6940 info@maico.de D07.21_EN_DSW-AV...