Preliminary Checks - RIB J-INV 3P-CRX Manual

Table of Contents

Advertisement

Available languages

Available languages

G
B

5. PRELIMINARY CHECKS

The preliminary checks must be carried out only by professionals and by paying maximum attention. The correct wiring of the motor and the limit switches is very important for the correct
featureing of the automation.
Unlock the motor and supply the system with power only after controlling the
wiring connections and checking the absence of short circuits
Manually bring the door to a total opening position and check the status of led
LS.OP.
Manually bring the door to a total closing position and check the status of led
LS.CL.
Manually bring the door to the middle of the run and then lock the motor.
Enter the parameter Manual Movement of MENU B and command the closure
of the door.
WARNING: pay attention with the moving door!
Enter the parameter Manual Movement of MENU B and command the opening
of the door.
WARNING: pay attention with the moving door!
6. MANUAL MOTION (Menu B - Manual movement)
This operation must be carried-out only by qualified personnel and by paying maximum attention.
The manual motion is an operation planned only for the phase of installation; it allows to move the door at a limited speed in both directions.
WARNING: the photocells and the safety edge are not monitored during this phase!
Access to parameter Manual Mov. of MENU B and confirm by pressing key P2
7. LEARNING
7.1 Learning the run of the door (Menu B - Final position)
It allows to define the parameters of the run of the door, such as the width of the run at normal speed and at slowed speed.
Check that the adjustment of the torque and the speed of the door are set before carrying out the learning phase.
Check that the door is closed before starting the learning phase.
Make sure you have correctly adjusted the electric limit switches.
Enter the parameter Final Position of MENU B and confirm by pushing P2
Exit the menu by scrolling the entries until you find EXIT
Check the status of the LEDs input by considering that all normally closed (NC)
inputs must have their corresponding led alighted.
• Led LS.OP. is OFF. Correct featureing
• Led LS.OP. is ON, but led LS.CL. is OFF; check the connection of the limit switches.
• Led LS.CL. is OFF. Correct featureing.
• Led LS.CL. is ON, but led LS.OP. is OFF; check the connection of the limit switches
The motor starts to move. Watch its sense of rotation:
• If the door opens, then stop the manual motion, disconnect the system from the
power and reverse the motor connections. Then try again.
• If the door closes, then stop the manual motion and go to the following phase
The motor starts to move. Watch its sense of rotation:
• If the door closes, then stop the manual motion, disconnect the system from the
power and reverse the motor connections. Then try again.
• If the door opens, then stop the manual motion and go to the following phase
Move the door by using keys P1 and P3.
Press key P2 or wait 15 sec. in order to exit the menu
• Start moving the door by pressing and releasing key P1 (START) or a Step-by-Step key.
• Push key P1 (START) or a Step-by-Step key when the door reaches the point where you want to
start the slowdown in the opening phase
• The door continues its run at reduced speed as far as it hits the opening limit.
• Once the opening limit has been reached, the door starts to close.
• Push key P1 (START) or a Step-by-Step key when the door reaches the point where you want to
start the slowdown in the closing phase
• The door continues its run at reduced speed as far as it hits the closing limit
• The programming is terminated once the closing limit is reached.
Note: in case no slowdown zones are set, then the control board will use the factory settings.