Advanced Features - RIB J-INV 3P-CRX Manual

Table of Contents

Advertisement

Available languages

Available languages

7.2 Learning the pedestrian run (Menu B – Ped. Position)
Learning the pedestrian run allows to define the position of pedestrian opening (PED command)
Check that the adjustment of the torque and the speed of the door are set before carrying out the learning phase.
Check that the door is closed before starting the learning phase.
Make sure you have correctly adjusted the electric limit switches
Enter the parameter Ped. Position of MENU B and confirm by pressing P2
Exit the menu by scrolling the entries until you find EXIT
8. ADJUSTMENT OF SPEED AND TORQUE (Menu B - Speed and torque)
ATTENTION: Execute the learning of the strokes every time these parameters are modified.
Once the parameters themselves are entered allow to adjust the corresponding parameters from a minimum up to a maximum value, according to the indications shown on the display.
The versatility of the control board allows an infinity of possible combinations: however it is recommended to adjust the settings by keeping into account the dimensions and weight of the door.
High speeds may be dangerous, as well as high torques.
Such regulations must be carried out only by professionals.
It is recommended to check the correct operation of the automation after any regulation.
It is highly recommended to learn the runs of the door each time these parameters are changed.

9. ADVANCED FEATURES

These are features and/or featureal modalities that can be activated by the user through the programming menu.
Automatic closing
Timed closing of the door from totally open position or pedestrian opening position. The "stop" command disables the automatic closing until a new command given by the user is received (S.S.,
CLOSE, etc).
PhotoAutoReclose
The door closes 3 s after the photocell intervenes in case the door is in a totally open or in a pedestrian open position.
Motor brake
To be used with motors with a strong inertia and the necessity to quickly stop the automation. Pay attention as the mechanics must be sized accordingly.
OFF: Brake disabled (Suggested for SUPER 3000 FAST)
1: Electronic braking feature (Don't use with SUPER 3000 FAST !)
2: Activation of the contact on the auxiliary card for an external brake. Active with still motor
3: Activation of the contact on the auxiliary card for an external brake. Active when motor is moving (By factory for SUPER 3000 FAST)
4: Pre-Activation of the contact on the auxiliary card for an external brake. Active with still motor
5: Pre-Activation of the contact on the auxiliary card for an external brake. Active when motor is moving
Dead Man
The motor moves only with permanent a command and not with just impulses: the motor opens if the key "open" is kept pressed, and the opposite operation applies with the key "close". WARNING:
this modality forbids all operations of automatic motion!
Condominium
All commands given via radio or by a step-by-step and/or a pedestrian opening keys involve only the opening of the door. The closing is related to the feature of automatic closing, which MUST BE
ABSOLUTELY ENABLED since every closing command is ignored.
Inv. On photocells
Allows to set if, once the photocell beam is interrupted, the door must reverse immediately (only in closing) or just after the removal of the obstacle (it applies both in opening and in closing)
Photocell test
This control board is equipped with a feature which allows to control the proper functioning of photocells before any movement of the motor.
The security of the system is therefore higher in case the photo-device breaks down (for example, if the relay of exit is stuck) or there is a undesired short circuit on the input of the photocells.
The control board indicates a possible fault by flashing only once when any key is pressed and aLS.OP. by not moving at all.
This check is made after the control board receives a command to move, but before the control board itself gives power to the motor.
Edge Inv.
Allows to set if, once the safety edge alarms itself, the door must stop or it must stop and then reverse (applies only in the phase of closing)
Edge Test
Functional test of the safety edge. Connect the safety edge as shown in the instructions by using the photocell test's clamp.
Pre-flashing
This feature commands a blinking BEFORE each movement in order to indicate the imminent movement itself.
Zone light
There is the possibility to use the auxiliary output as a courtesy light or as a light zone (always lit-on as long as the door is open)
Start moving the door by pressing and releasing P1 (START) or Step-by-Step key.
When the door reaches the position of pedestrian opening, push P1 (START) or step-by-step key => The
door moves again in closing.
As door hits the closing limit switch, then the programming is ended.
43