SYSTEM LAY-OUT
- IDRO operator
- Tuned aerial
- Flashing lamp
- Key selector
- Photoelectric cells (external)
- Photoelectric cells (internal)

PRE-INSTALLATION CHECKS

The leaf must be fixed firmily on the hinges to the pillars, must not be flexible
during the movement and must move without frictions.
Before the installation of IDRO, verify all dimensions etc.
There's no need for any modification, if the gate is like that shown in Fig. 1.
Gate features must be uniformed with the standards and laws in force. The
door/gate can be automated only if it is in a good condition and its conditions
comply with the EN 12604 norm.
- The door/gate leaf does not have to have a pedestrian opening. In the
opposite case it is necessary to take the appropriate steps, in accordance
with EN 12453 norm point 6.5.1 (for instance; by preventing the operation
of the motor when the pedestrian opening is opened, by installing a safety
microswitch connected with the control panel).
No mechanical stop shall be on top of the gate, since mechanical stops are
not safe enough.
ELECTRICAL SAFETY DEVICES
In addition to compliance to all mechanical safety regulations, gates with leaf
length exceeding 1.8 m must be fitted with two pairs of photocells capable of
interrupting gate movement.
The photocells must be installed at a height of 40 - 60 cm between the gate
posts on the outside of the structure.
The other two photocells must be installed at the same height as the
previous ones on the ends of the gate leafs to form a barrier between the
leafs when open.
Gate movement must be indicated by a flashing unit placed near the gate.
Use the B2-CRX (for one or two single-phase motors) electronic control unit.
For connections and technical data of accessories refer to the appropriate
booklets.
1
TECHNICAL DATA
Max. leaf length
Max. leaf weight
Max. travel
Average opening time
Thrust force
Power supply
Motor capacity
Power absorbed
Capacitor
Normative cycles
Daily operations suggested
Service
Guaranteed consecutive
Lubrification
Weight
Noise
Volume
Operating Temperature
Protection
* In the case of leaf longer than 1,6 m, an electric lock must be fitted to ensure efficient closing.
** In the case of leaf longer than 1,8 m, an electric lock must be fitted to ensure efficient closing.
*** IDRO 27 SUPER slows down in the 2 cm of the stroke.
19
27
27/R
27/1B
SUPER/R
m
3
3*
6
kg
400
700
cm
27
27***
s
16
40
N
2500
230V~ 50/60Hz
W
180
A
1
µF
6,3
300 - 15s/2s
500 - 23s/2s
300
500
%
80
100
200
OX SUPER
kg
10
11,4
db
<70
m
3
0,0086
°C
-20 ÷ +55
IP
55
G
B
1
27
39/1B
39/R
SUPER/1B
39/2B
6**
7
7**
1000
39
50
6400
220
1,1
12,5
800 - 45s/2s
800
90
800
13,6
0,0084