Setting
Pr.
Name
range
Home position shift
1285
0 to 9999
amount lower 4 digits
Home position shift
1286
0 to 9999
amount upper 4 digits
Travel distance after
1287
proximity dog ON lower
0 to 9999
4 digits
Travel distance after
1288
proximity dog ON
0 to 9999
upper 4 digits
Home position return
1289
0 to 200%
stopper torque
Home position return
1290
0 to 10s
stopper waiting time
Position control
1292
terminal input selection 0, 1
Roll feeding mode
1293
0, 1
selection
Position detection lower
1294
0 to 9999
4 digits
Position detection
1295
0 to 9999
upper 4 digits
Position detection
1296
0 to 2
selection
Position detection
1297
0 to 32767
hysteresis width
Second position control
-1
1298
0 to 150s
gain
Second pre-excitation
1299
0, 1
selection
1300 to
Communication option parameters
1343
P/PI control switchover
1348
0 to 400Hz
frequency
Emergency stop
1349
0, 1, 10, 11
operation selection
1350 to
Communication option parameters
1359
Starting times lower 4
1410
0 to 9999
digits
Starting times upper 4
1411
0 to 9999
digits
Motor induced voltage
1412
constant (phi f)
0 to 2, 9999
exponent
Second motor induced
1413
voltage constant (phi f)
0 to 2, 9999
exponent
0, 1, (2, 3, 4, 5,
Load characteristics
1480
81, 82, 83, 84,
measurement mode
85)
Load characteristics
0 to 400%,
1481
load reference 1
8888, 9999
Load characteristics
0 to 400%,
1482
load reference 2
8888, 9999
Load characteristics
0 to 400%,
1483
load reference 3
8888, 9999
Load characteristics
0 to 400%,
1484
load reference 4
8888, 9999
Load characteristics
0 to 400%,
1485
load reference 5
8888, 9999
Load characteristics
1486
0 to 590Hz
maximum frequency
Load characteristics
1487
0 to 590Hz
minimum frequency
Upper limit warning
1488
0 to 400%, 9999 20%
detection width
Lower limit warning
1489
0 to 400%, 9999 20%
detection width
Upper limit fault
1490
0 to 400%, 9999 9999
detection width
Lower limit fault
1491
0 to 400%, 9999 9999
detection width
Load status detection
signal delay time / load
1492
0 to 60s
reference measurement
waiting time
1499
Parameter for manufacturer setting. Do not set.
Pr.CLR Parameter clear
(0), 1
ALL.CL All parameter clear
(0), 1
Err.CL Fault history clear
(0), 1
Pr.CPY Parameter copy
(0), 1 to 3
Pr.CHG Initial value change list ―
IPM
IPM initialization
0, 3003
AUTO Automatic parameter
setting
Pr.Md Group parameter setting (0), 1, 2

Differs according to capacities.
• 6%: FR-A820-00046(0.4K), 00077(0.75K) and FR-
A840-00023(0.4K), 00038(0.75K)
• 4%: FR-A820-00105(1.5K) to 00250(3.7K) and FR-
A840-00052(1.5K) to 00126(3.7K)
• 3%: FR-A820-00340(5.5K), 00490(7.5K) and FR-
A840-00170(5.5K), 00250(7.5K)
• 2%: FR-A820-00630(11K) to 03160(55K) and FR-
A840-00310(11K) to 01800(55K)
• 1%: FR-A820-03800(75K) or higher and FR-A840-
02160(75K) or higher

For FR-A820-03160(55K) or lower and FR-A840-
01800(55K) or lower
Initial

For FR-A820-03800(75K) or higher and FR-A840-
value
02160(75K) or higher

For FR-A820-00490(7.5K) or lower and FR-A840-
0
00250(7.5K) or lower

For FR-A820-00630(11K) or higher and FR-A840-
00310(11K) or higher
0

Differs according to capacities.
• 4%: FR-A820-00490(7.5K) or lower and FR-A840-
00250(7.5K) or lower
2048
• 2%: FR-A820-00630(11K) to 03160 (55K) and FR-
A840-00310(11K) to 01800 (55K)
• 1%: FR-A820-03800(75K) or higher and FR-A840-
0
02160(75K) or higher

Differs according to the voltage class. (200 V class/400
V class)
40%

The setting is available only when a Vector control
compatible option is installed. To check the availability
0.5s
of the parameter for each option refer to the Instruction
Manual (Detailed).

The parameter number in parentheses is the one for
0
use with the LCD operation panel and parameter unit.

Differs according to types. (FM type/CA type)
0

The setting is available only with the CA type.

The setting value "60" is only available for Pr.178, and
"61" is only for Pr.179.
0

The setting values "92, 93, 192, and 193" are only
available for Pr.190 to Pr.194.
0

Simple mode parameters. (Initially set to the extended
mode.)
0

Parameters for CC-Link IE Field Network
communication

When Pr.160="9999", only the simple mode
0
parameters and the parameters for CC-Link IE Field
Network communication are displayed.
-1
25s

The setting is available when the PLC function is
enabled.
0
0Hz
0
0
0
9999
9999
0
9999
9999
9999
9999
9999
60/50Hz

6Hz
1s
0
0
0
0
0
0
19
PARAMETER LIST