HP Metal Jet S100 User Manual page 84

Powder management station
Hide thumbs Also See for Metal Jet S100:
Table of Contents

Advertisement

NOTICE:
Do turn the cover over after removing and keep it as flat as possible to avoid powder
spillage. Clean the cover before placing it in its parking place.
WARNING!
Check the manual powder intake nozzle
Look at the nozzle of the manual powder input hose and check for any obvious damage.
If you see any hole in the mesh, contact your service representative.
Once a month
Clean the mixer lid area
Always perform the steps of the procedure in the order presented.
Content TBD.
Once a year
Replace the sieve inlet filter (791A0A)
Prepare for replacement
Always follow the steps of the procedure in the order presented.
1.
Ensure that the Load station is not in use.
2.
To replace the vacuum port inlet filter you need one 791A0A - HP Metal Jet Powder Sieve Inlet Filter
provided in the yearly maintenance kit. Once filter is required for this operation.
3.
You are recommended to wear safety goggles, gloves, a safety mask, and safety boots. The area is
marked with warning symbols.
WARNING!
personal injury or damage to the product.
80
Chapter 4 Maintenance
Explosion hazard. Mechanical sparks and static electricity may be generated.
Failure to follow the guidelines marked with warning symbols could result in serious

Advertisement