VAT 64246-UEHC-0001 Installation, Operating, & Maintenance Instructions page 23

Control gate valve with logic interface
Table of Contents

Advertisement

Series 642
4.5.3.2
Sensor power wiring external
603685EA
INSTALLATION
VAT fuse recommendation: (a) 5AF, (b) min. 3A
Use shielded sensor cable(s). Keep cable as short as possible, but locate it away
from noise sources.
Connect Power supply (+24 / GND) at power 5 pol. male connector and Sensors
(0V / + / -) at DB–15 female sensor connector exactly as shown in the drawing
above!
Edition 2013-08-22
Pins 2 and 3 must be
bridged for operation.
An optional switch
would allow for motor
interlock to prevent
valve from moving.
S C 1 084 A
23/73