This message informs you that the main PCB does not communicate correctly with the Control Board.
(Color-wheel error) This message will appear after the reset of the fixture if the magnetic-indexing circuit
malfunctions (sensor failed or magnet missing) or the stepping-motor is defective (or its driver circuit on the
main PCB). The color-wheel is not located in the default position after the reset.
This error message informs you that the fixture was overheating (occured if the ambient temperature is 45° C
or more) and that the relay switched off the lamp. This message will appear on the display until the
temperature will be on a suitable level, then the display will show the HEAt message meaning the lamp is too
hot (explanation see above).
This message appears if the lamp lighting sensor is failed. Please contact your dealer.
Caution: Please note that this function is disabled if the lamp light sensor is switched off (function "EnSn").
This message will appear if the fixture was shortly disconnect from the mains.
(PAN-yoke movement error) This message will appear after the reset of the fixture if the yoke's magnetic-
indexing circuit malfunction (sensor failed or magnet missing) or the stepping-motor is defective (or its driving
IC on the main PCB). The yoke is not located in the default position after the reset.
(TILT-head movement error) This message will appear after the reset of the fixture if the head's magnetic-
indexing circuit malfunctions (sensor failed or magnet missing) or the stepping-motor is defective (or its
driving IC on the main PCB). The head is not located in the default position after the reset.
This message will appear if the frequency of the mains is not standard 50 or 60 Hz.

CLEANING AND MAINTENANCE

The operator has to make sure that safety-relating and machine-technical installations are inspected by an
expert after every four years in the course of an acceptance test.
The operator has to make sure that safety-relating and machine-technical installations are inspected by a
skilled person once a year.
The following points have to be considered during the inspection:
1) All screws used for installing the devices or parts of the device have to be tighly connected and must not
be corroded.
2) There must not be any deformations on housings, fixations and installation spots (ceiling, suspension,
trussing).
3) Mechanically moved parts like axles, eyes and others must not show any traces of wearing (e.g. material
abrading or damages) and must not rotate with unbalances.
4) The electric power supply cables must not show any damages, material fatigue (e.g. porous cables) or
sediments. Further instructions depending on the installation spot and usage have to be adhered by a
skilled installer and any safety problems have to be removed.
DANGER TO LIFE!
Disconnect from mains before starting maintenance operation!