6.4.7 Battery care

Before handling batteries, read the
relevant safety precautions and act
accordingly.
If the battery is still dry, it must be activated as
described in section 6.4.7.2.
The battery must be in operation within 2 months
from being activated; if not, it needs to be recharged
first.

6.4.7.1 Electrolyte

Read
the
safety
!
carefully.
Electrolyte in batteries is a sulphuric acid solution in
distilled water.
The solution must be made up before being
introduced into the battery.
6.4.7.2 Activating a dry-charged battery
– Take out the battery.
– Battery and electrolyte must be at equal
temperature above 10°C.
– Remove cover and/or plug from each cell.
– Fill each cell with electrolyte until the level
reaches 10 to 15 mm above the plates, or reaches
the level marked on the battery.
– Rock the battery a few times so that possible air
bubbles can escape; wait 10 minutes and check the
level in each cell once more; if required, add
electrolyte.
– Refit plugs and/or cover.
– Place the battery in the compressor.

6.4.7.3 Recharging a battery

Before and after charging a battery, always check the
electrolyte level in each cell; if required, top up with
distilled water only. When charging batteries, each
cell must be open, i.e. plugs and/or cover removed.
instructions
Use a commercial automatic battery
charger
manufacturer's instructions.
Apply with preference the slow charging method and
adjust the charge current according to the following
rule of thumb: battery capacity in Ah divided by 20
gives safe charging current in Amp.
To keep a battery charged, use the unit's battery
charger.
Do not use this battery charger to charge an empty

battery.

according
to
its
- 70 -
6.4.7.4 Maintaining the battery voltage
To maintain the battery voltage, use the unit's
automatic battery charger.
– Battery charger EEC/AUS: 240 VAC / 24 VDC -
100 VA
– Battery charger USA: 120 VAC / 24 VDC -
100 VA
When power is supplied to the charger, the battery
voltage will be kept within preset limits.
Three LEDs on top of the battery charger show the
charging condition:
– Green: AC supply voltage present
– Yellow: Battery voltage high
– Red: DC voltage present / unit charging
Do not use the unit's automatic
!
battery charger to charge an empty
battery.
In
this
commercial
automatic
charger (see section 6.4.7.3).
6.4.7.5 Battery maintenance
– Keep the battery clean and dry.
– Keep the electrolyte level at 10 to 15 mm above
the plates or at the indicated level; top up with
distilled water only.
– Keep the terminals and clamps tight, clean, and
lightly covered with petroleum jelly.